Member Since

2006

Chang Cheng Electrical Equipment Group Co.,Ltd.

 
  • Miniature Circuit Breaker (YCBKN)
    AF Poles Type Rated current(A), In Ulitimatebreakingcapacity(kA rms), Icu 63 1 BKN 1, 2, 3,4, 6, 10,16, 20, 25,32, 40,50, 63 1pole: 6kA at 230/400AVC2~4pole: 6kA at 400AVC
  • Miniature Circuit Breaker (BH,BH-S,BH-P)


     
    { YBBH Circuit Breaker }
    ApplicationYB series miniature circuit breaker has characteristic of small size, light weight, novel structure and excellent performance.They are mounted in the illuminating distribution board and used in guesthouses, block of flats, high buildings, squares, airports, railway stations, plants and enterprises etc, in AC circuits 240V (single pole)up to 415V (3 pol
  • Miniature Circuit Breaker (YCL360)


     
    { YCL360 Residual Current Circuit BreakerRCCB }
    YCL362-63A0.03A
    YCL364-63A0.03A
    YCL-362
    YCL-364
    Application
    The item is in accordance with standards of IEC1008-1 and GB16916.1-1997, applying to the circuit of AC 50/60Hz, 240V single phase,415V three phases or below it for industrial and mining enterprise, trade building, commerce and family. It is mainly used for preventing electri
  • Residual Current Circuit Breaker (NFIN)


     
    { NFIN Residual Current Device(RCD) }
    NFIN2P 40A 0.03A
    NFIN 2P 63A 0.1A
    Application
    The Residual Current Device(RCD) NFIN is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, hotels and families. It can be used in circuits single phase 240V, three phases 415V, rated frequency 50 or 60Hz. It can cut off the fault circuit immediately on t
  • Earth Leakage Circuit Breaker (PG230,PG430)


     
    { PG230 PG430 Earth Leakage Circuit Breaker }
    Application
    PG230& PG430 breakers are suitable in AC 50Hz, 250/440V circuit with earth leakage protection. The rated current is adjusted from 10A and 60A. User can select suitable current to better protection against overload and short circuit.
    Technical Data
    Type
    PG230/PG430
    Poles
    2P,4P,
    Rated voltage(V)
    250/440,
    Rated current(A
  • Residual Current Circuit Breaker (ID)
    c.sh/english/Article_Show2.asp ArticleID=403 { ID Residual Current Circuit BreakerRCCB }
  • Moulded Case Circuit Breaker (YCM3)


     
    { YCM3 Moulded Case Circuit Breaker }
    Application
    YCM3 series moulded case circuit breaker is one of the most advanced typebreaker in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection in circuit of AC 690V 50/60Hz,rated current from 12.5A to 630A. Its rated insulation voltage is 690V. It can make
  • Moulded Case Circuit Breaker (YCM2)


     
    { YCM2 Moulded Case Circuit Breaker }
    Application
    YCM2 series moulded case circuit breaker, is suitable for the circuit of AC 50Hz (or60Hz),rated insulation Voltage 660V, rated operating Voltage under AC 660V, 250V(DC),rated operating current 10A-800A. It is for distributing energy of electricity and infrequent making and circuit under normal conditions. The MCCB rated current under 400
  • Moulded Case Circuit Breaker (NF)


     
    { NF Moulded Case Circuit Breaker }




    NF50-CP
    NF100-CP
    NF250-CP



    NF-100SS 3P
    NF-250SS 3P

    NF-100SS 4P







     Specifications
    NF-CP
    Pole number
    Rated current(A)
    Testing voltage(V)
    (P1/p2) Ica/Ics Breaking capacity(KA)
    230
    NF-50CP
    3
    5 10 15 20 30 40 50
    600
    5/2
    5/2
    2.5/1
    2.5/1
    NF-60CP
    3
    60
    600
    5/2
    5/2
    2.5/1
    2.5/1
    NF-100CP
    3
  • Moulded Case Circuit Breaker
    MOULDED CASE CIRCUIT BREAKERDESCRIPTION Available in two frame sizes from 25 to 800 amps.Loadine series of moulded case circuit breakers provide overload and short-circuit protection for the full
 
Page 1 of 10
Go to Page