Member Since

2005

Expanding Industry Limited

 
  • Sale EX-941 Anaesthetic Workstation
    Main technical data
    Technical parameters of Anaesthetic Workstation
    O2 supply range:
    Rated working pressure: 0.4Mpa, allowable range: (0.27~0.55)
    Mpa,  central supply or gas cylinder.
    Adjusting range of flow: O2: (0.1~10) L/min, N2O: (0.1~10) L/min
    Breathing circuit: Working mode: closed, semi-closed (1~4) kpa, semi-opened;
    The resistances of inspiration and expiration are all not more
  • Sale EX-931 Anesthesia machine
    Main technical data
    Working Conditions
    Environmental temperature :5~400C
    Relative humidity : not greater than 80%
    Atmosphare pressure:86~106kPa
    Working gas Pressure:0.4+0.1MPa
    AC Power:220+22V,50+1Hz
    Input Power:30W
    Oxygen flow meter :0.1~10L/min (adjustable)       Oxygen flusher:35~75L/min
    Enflurane vaporizer:0~5Vol%(O2flow=1L/min)(Vaporizer for isoflurane is ready for opti
  • Sale EX-832   Multifunctional  Ventilator
    MAIN FEATURE
    Gas driven electronically controlled.
    PEEP function.
    End-inspiratory holding (inhalation platform, end-inhalation pause) function.
    SIGH function
    I/E function
    All the parameters display on the panel.
    Simple to operate.
    Safe alarm and protection function.

    MAIN TECHNICAL SPECIFICATION:
    Mode: IPPV, SIPPV(A/C auxiliary/controlling ventilation), SIMV, IPPV+SIGH, SPONT
  • Sale Computerized High-frequency Ventilator for Infant
    MAIN FEATURE:
    The tidal air can letout with constant pressure, constant current or accurately adjustable flow.
    Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant.
    Evident effectiveness of treating ARDS can be shown with inserting small tube and jetting oxygen through nasal vestibule, which i
  • Sale Automatic Syringe Pump PP-S15
    Specifications
    1.1 Ambient temperature: -5 ---- 40
    1.2 Relative humidity: below 80%
    1.3 Power supply: AC220V?2V, 50HZ?HZ
    1.4 Internal batteries: 12V?.5V,over 2 hours with fully charged
    1.5 Atmospheric Pressure: 860hpa~1060hpa
    1.6 Storage Temperature: -40℃~+55℃
    Basic Parameters
    2.1 Dimensions: L譝譎 in mm: Approximately 320?45?20
    2.2 Weight: Approximately 3 kg
    2.3 Power Wast
  • Single channel syringe pump: PP-S13/14
    Syringe Pump PP-S13 PP-S14

    Body weight mode (PP-S14 only)
    Occlusion pressure selected
    Automatically release pressure after occlusion alarm
    Automatically recognize syringe size
    Preset volume infused
    Total volume indicator
    KVO
    Fast-injection control
    Lock the fast key when infusing
    Lock the flow rate setting keys when infusing
    Regulating flow rate conveniently
    Audio and video alarms
    A
  • sell Infusion  Pump VP-111
    Preset volume infused
    Flow rate indication
    Transfusion condition indication
    Infusion set look-in window
    Total volume indication
    With Bubble evacuate function & Door-lock handle
    KVO
    Fast-injection function
    Regulating flow rate conveniently
    Audio and video alarms
    AC and DC indicator  
    Basic parameter
    Flow rate: 1ml/h~999ml/h, add or minus mete are 1ml, 10ml and 100ml respectively.
    T
  • sell Palmtop Patient Monitor PM002P
    Palmtop Patient Monitor PM002P
    Palmtop Patient Monitor
    Clear and bright LCD
    Built-in rechargeable battery, 12 hours run
    3-lead ECG, defibrillation protection
    Audible and visual alarm
    36 hours trend data memory
    Networking
    SPECIFICATIONS:
    ECG
    Lead: I, II, III
    Frequency Range: 0.05 ~ 100Hz
    Gain Selection: x8, x4, x2, x1,
    ECG Calibration: 1mV
    Scan Speed: 12.5/ 25/ 50mm/sec
  • Three Channel ECG-03A
    FEATURES:
    1.Three channel interpretation ECG machine
    2.Simultaneous 12 leads acquisition
    3.8 patients save/copy/communication
    4.LCD to display 12 lead ECG waveform
    5.print:3 lead waveform, measurement result, interpretation result
    6.Built in RS232 interface
    7.AC/DC power, built in rechargeable lithium battery
    8.Option:RS232 software, RS232+USB software
    SPECIFICATIONS: 
    Lead 
     
  • Six Channel ECG-061
    Six Channel ECG-061
    Experts

    Large LCD Display Waveform & Manu
    Six-channel & Multi Form Printing
    12 Lead Simultaneous Acquisition
    Measurement & Interpretation
    RS232 interface, software is optional
    16sets data and analysis result memory is optional
    FEATURES:

    1. Large LCD display six-channel ECG waveform, manus and parameter settings.
    2. Standard six-channel and multi printing for
 
Page 1 of 2