Hezhong Electric Co.,Ltd.

 
  • HP3 Series PLC (HAPC-K3)
    HP3 series micro Programmable Logic Controller is advanced PLC product applied in machine control and small-scale process control of plant automation field. Compared with the products of the same kind in the market, it is a newcomer but it goes beyond the primary stage of PLC development and integrates a great number of advanced technologies and advanced functions into the logic controller, so it
  • HCH8 Series Houeshold AC Contactor (HCH8 Series)
    The products is mainly applicable to a power system of AC 50Hz(or 60Hz), rated working voltage up to 230V , and in a line of application class AC-7a with rated working voltage up to 230V and rated working current up to 20A.It is used to remotely close or/and switch off the line.
       The product is in conformity with the standards: GB 17885 IEC 1095
     
    Type and meaning 
    HCH8-20
    │ &#
  • HC1-F(CJX2-F) Accessories Series AC contactor (HC1-F(CJX2-F))
    The contact system of the contactor is of direct action type and double-break arrangement. The lower base frame of the contactor is made of shaped aluminum alloy and the coil is of plastic enclosed structure. The coil is assembled with the magnet yoke to be an integrated one. They can be directly taken out from or ed  the contactor. It is convenient for user's applecation and maintenance.
      
  • HC1-F(CJX2-F) Series AC contactor (HC1-F(CJX2-F))
    The product is mainly applicable to a circuit of 50/60 Hz, rated voltage up to 1000VAC and rated current up to 780A. It can combine with an overload relay to make a Starter to switch on/off the circuit for overload protection.
      The product is conformed to GB14048.4 & IEC 60947.4 standard.
  • HC1-D(CJX2-D) Series AC contactor (HC1-D(CJX2-D) Series)
    The product is mainly used in a circuit of AC 50Hz or 60Hz , rated working voltage up to 660V and rated working current up to 95A under application class of AC-3. It is used to remotely make and break the circuit. Connected with a proper thermal relay, it can form an electromagnet starter to protect a circuit in which overload running may occur, and to be used for frequent start and control of an
  • CABLE ACCESSORIES (F ,CM ,IT)
    CABLE MARKERS 
     
    Material: Made from PVC, oil and erosion control, heat resisting up to 85癈
    Structure: The inside is hollow, but elastic, The diameter can change with the needed wire.
    PVC INSULATING TAPE 
    Type Specification Size
    IT10-1 White insulating tape 8YARD, 10YARD, 15YARD, 18YARD, 20YARD
    IT10-2 Black insulating tape
    IT10-3 Green insulating tape
    IT10-4 Red insulating tape
    I
  • NFIN Series residual current circuit breaker (NFIN Series)
    APPLICATION 
     
       NFIN Residual Current Circuit Breaker provide the function of isolation switching and earth leakage protection of electrical circuits.And alsoprovide the indirect protection of the operators body against the dangerous effects of electric current and provide the protection of the fire caused by the electrical circuit fault.
    Main Technical parameter 
    Type NFIN RCCB
    Numb
  • HC1-E(CJX2-E) Series AC contactor (HC1-E(CJX2-E) Series)
    HC1-E Series AC Contactor is suitable for circuits with the rated voltage up to 690V AC, 50Hz/60Hz and 250V DC and rated current of 6A and 9A for frequent making and breaking in starting and controlling of the AC motor . As machine interlocking contactor, combined with the auxiliary contact group , air delayer , and the thermal relay , it is combined into the electromagnetic starter.
  • HY1 Surge protector (HY1)
    APPLICATION 
     
      HY1 series surge protective device (SPD) is suitable for AC 50/60 Hz.380V and the following electric power system, such as TT,IT, TN-S,TN-C and TN-C-S for protecting electric net shocked by the thunder or over voltage.
    Technical parameters 
    Maximum continuous operating voltage : Uc~ 140 275 320 385 420 550V
    Test grade :
    Voltage protect level: Up 0.8 1.2 1.5 1.8 2.0 2.5
  • DZ47-63 Series miniature circuit breaker (DZ47-63 Series)
    APPLICATION 
     
       DZ47 series circuit breakers are mainly applied to AC 50 Hz/60 Hz circuit with rated voltage 230V/400V , rated current up to 63A and provide circuits of modern buildings with overload and short-circuit protections, and it can also be used for operating and isolating the circuit infrequently.
    Construction features 
      DZ47 series miniature circuit breakers are composed
  • HM1 Series Moulded Case Circuit Breaker (HM1 Series MCCB)
    The breaker is mainly used in distribution network of AC 50Hz or 60Hz, rated voltage up to 690V, rated working current up to 1600A to distribute electric power and to protect the line and the equipment from being damaged due to overload, short circuit and under-voltage. It can also be used for infrequent motor start and for motor overload, short circuit and under-voltage protections.

    model F
  • HP2 series switching mode power supply (SP Series)
    Internal-Installed EMI filter condenser
    Input frequency: 47-63HZ
    Output voltage stability:+-0.5%
    Can be used for DIN installation (EN50022-35)
    All range voltage input (85-264VAC,120V-370VDC)
    Output voltage inching range (-5%~+10%,adjusting potentiometer V)
    Have the function of soft-start (to limit the peak current of start and the pressure of the voltage to the components)
    The curren
  • HP2 Intelligent Controller (SR Series)
    HP2 intelligent controller is a new product of programmable controller of super mould, programming with FBD, simple and easy to learn. Being used together with voice module and remote module, it can achieve the telephone remote controlling, wireless control, voice prompting and auto-dialing functions. And being used with expansion module, the input/output points can be expanded to satisfy your con
  • HP1 Series PLC (Programmable Intelligent Controller (AF Series)
    HP1 series mini PLC (intelligent controller) is a new type of programmable controller. As it is programmed by the means of FBD (Function Block Diagram), it is more simple and easier to learn the programming of HP1 than the conventional PLC programming (ladder diagram and instruction). In the design concept of the products of AF series, the machine in the conventional separating PLC is combined wit
  • Soft Starter HZR1-S
    The motor starter with the features of small volume, small starting frequency, energy saving, and multi-protection and so on, which improved the production efficiency that is an idea  starter.
    Technical characteristics
    No phase order required for the power.
        Double insulation of the power prevents control parts from all kinds of disturbance.
        Soft start can provide smooth and
  • HC1-K(CJX2-K) Series AC contactor (HC1-K(CJX2-K))
     Ambient temperature:-5℃+40℃, average value not excee ding +35℃within 24 hours
    Altitudes: not exceeding 2000mm
    Atmospheric Conditions: relative humidity not exceeding 50% at +40℃.
    Temperature shall not exceed +25℃in humid month while max-imum 90% humidity is allowed
    Pollution grade: 3
    Mounting class: III
    Mounting condition :tilt angle not exceeding ?℃
  • Shape and specification 1 (HBP5)
      HBP5-BW3361 Green,directness,NO,220V
    HBP5-BW3462 Red,directness,NC, 220V
    HBP5-BW3561 Yellow,directness,NO, 220V
    HBP5-BW3371 Green,resistance,NO,220V
    HBP5-BW3472 Red,resistance,NC,220V
    HBP5-BW3571 Yellow,resistance,NO,220V
  • HBP7 Series economic pushbutton And Indincatinglam (HBP7)
  • HD22 Indicator Lamp Series (HD22)
    Have many color.
  • HR17 Fuse isolator (HR17)
    HR17 Series Switch is rated frequency is 50 Hz (or 60 Hz), rated insulation voltage 800V, rated working voltage up to 690V, and rated working current up to 630A . It can be used in the distribution circuit of high short-circuit current and the motor circuit, serving for power switch, isolating switch and emergency switch as well as circuit protector. Generally, it cannot be directly used for swi
 