NANJING GOLD CATTLE HIGH SPEED ANALYZER CO.,LTD

 
  • JN8608-2002 High-speed Computers Carbon and Sulfur Analyzer
    Main Specifications: Determination of: carbon 0.02-10.00% (to change that kind of) sulfur 0.001-2.00%; Measuring Time: 45 seconds or so; Measurement precision: precision: the GB/T223.69-1997
  • 8628-5A Grating Spectrometer
    Main Specifications: The wavelength range :330-820 nm (continuous wavelength tunable) Wavelength Accuracy: < 2nm Wavelength reproducible: <0.5 nm Transmittance linear precision: < 0.5 nm% (T) The
  • 721B Spectrophotometer
    Main Specifications: The wavelength range :350-820 nm Wavelength Accuracy: < 3nm Wavelength reproducible: <1 nm Transmission measurement range :0-100% (T) The absorbance measurement range :0 - 1.999
  • Intelligent Three Elements Analyzer
    Main Specifications: Analysis: photoelectric colorimetric analysis Range Range: absorbance value of 0 to 1.999 A, the concentration of 0 to 99.99% Measurement precision: the GB223.3 - 5.88 standard
  • Intelligent Three Elements Analyzer
    Main Specifications: Analysis: photoelectric colorimetric analysis Range Range: absorbance value of 0 to 1.999 A, the concentration of 0 to 99.99% Measurement precision: the GB223.3 - 5.88 standard
  • Carbon-sulfur Analyzer
    Main Specifications: Measuring range: carbon: 0.02% to 12.8% (that kind of change required) S: 0.001% to 3.00% Measuring Time: 45 seconds or so (not including sampling, sampling time) Measurement
  • The Measurement of Carbon Sulfur Analyzer
    Main Specifications: Measuring range: carbon: 0.01% to 12.7% S: 0.003% to 2.00% Measuring Time: about 45 seconds Measurement precision: the GB/T223.69-97 GB/T223.68-97 standards Supply voltage: 220 V
  • High-frequency Infrared Carbon and Sulfur Analyzer
    Main Specifications:
     Measuring range: carbon 0.0001% -6.0000% (can be expanded to 99.999%)
    Sulfur 0.0003% -2.00% (can be expanded to 99.999%)
      Measuring Time: 25-60 seconds adjustable (usually in the 35 seconds or so)
      Measurement accuracy: carbon meet ISO9556-94 standards
    Sulfur meet ISO4935-94 standards
     Electronic scales: Weighing range 0-100 grams reading accuracy: 0.001 g
  • Multi-element Analyzer
    Specifications
    * Photoelectric colorimetric analysis;
    * Range Range: absorbance values 0-1.99 A concentration of 0-99.99%
    * Measurement Accuracy: meet GB223.3-5-88 standards
    * Measurable elements: manganese, phosphorus and silicon, nickel, molybdenum, chromium, titanium, copper, lead, zinc, iron, aluminum, magnesium, Rare Earth, niobium, vanadium, and other elemental analysis
    Main feat
 