  • UL1015 PVC Hook up wire
    PVC Insulated Hook-up Wire

    Descriptions
    -UL Style1015, CSA AWM IA
    -Maximum Temperature Rating: 105 degree
    -Maximum Voltage Rating: 600V
    -Referenced Standard: UL758, UL1581, CSA C22.2 No.210.2
    -File No: E170689, LL109915
    -Solid or stranded, tinned or bare copper conductor, 32-16AWG
    -Color-coded PVC insulation
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 1015 E170689 VW-1 105 de
  • UL1007 PVC Hook up wire
    PVC Insulated Hook-up Wire

    Descriptions
    -UL Style1007, CSA AWM IA
    -Maximum Temperature Rating: 80 degree
    -Maximum Voltage Rating: 300V
    -Referenced Standard: UL758, UL1581
    -File No: E170689, LL109915
    -Solid or stranded, tinned or bare copper conductor, 32-16AWG
    -Color-coded PVC insulation
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 1007 E170689 VW-1 80 degree 300V () AWG XINYA-
  • UL1015 PVC Hook up wire
    PVC Insulated Hook-up Wire

    Descriptions
    -UL Style1015, CSA AWM IA
    -Maximum Temperature Rating: 105 degree
    -Maximum Voltage Rating: 600V
    -Referenced Standard: UL758, UL1581, CSA C22.2 No.210.2
    -File No: E170689, LL109915
    -Solid or stranded, tinned or bare copper conductor, 32-16AWG
    -Color-coded PVC insulation
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 1015 E170689 VW-1 degree
  • Japan PSE Power cord
    Japan PSE Power cord
    (H) VSF, (H) VFF, (H) VCT, (H) VCTF, (H) VCTFK
    Descriptions
    -Maximum Temperature Rating: 75癈
    -Maximum Voltage Rating: 300V
    -Annealed and stranded copper conductor
    -PVC insulation and jacket
  • HIGH TEMPERATURE PTEE INSULATION WIRE
    Descriptions
    -UL Style1331
    -Temperature Rating: -80~+150癈
    -Maximum Voltage Rating: 600V
    -Referenced Standard: UL758, UL1581, CSA C22.2 No.210.2
    -File No: E170689, LL109915
    -Solid or stranded, silver-plated or tinned copper conductor, 10-30AWG
    -Color-coded PTEE insulation
    -Passes UL VW-1, CSA FT1 flame test
    -Uniform insulation thickness of wire to ensure easy stripping and cutting

    Appl
  • Japan PSE Power cord
    Japan PSE Power cord
    (H) VSF, (H) VFF, (H) VCT, (H) VCTF, (H) VCTFK
    Descriptions
    -Maximum Temperature Rating: 75癈
    -Maximum Voltage Rating: 300V
    -Annealed and stranded copper conductor
    -PVC insulation and jacket
  • AEX, AVX heat resistant low voltage cable
    Descriptions
    -Referenced Standard: JASO D608-92
    - Conductor: 0.5f-8mm2 annealed tinned or bare copper
    -XLPE insulation
    Applications
    - Connection wiring of automobile resistant to fire, oil, abrasion and heat
  • DVI Cable
    Descriptions
    -UL Style20276, CSA AWM IA
    -Maximum Temperature Rating: 80癈
    -Maximum Voltage Rating: 30V
    -Referenced Standard: UL758, UL1581
    -File No: E170689, LL109915
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 20276 E170689 VW-1 80癈 30V XINYA-B LM DVI CABLE

    Applications
    -Used for Digital TV, DVD player, Set-top box and other audio/video product
  • CAT5e
    Descriptions
    -Can be used as local area network cable.
    -Construction: UTP 24AWG(7/0.205*4P)~(1)stranded wire
    or 24AWG(1/0.517*4P)~(2)solid wire. STP26AWG(7/0.165*4P+4P+Mylar+DW+AL/MY)
    or 24AWG(7/0.205*4P+MY+DW+AL/MY)
    Characteristics
    Jacket OD
    Pair NO Patch Core LAN Cable Unit
    4P UTP 5.5 5.2~5.5 Mm
    2P UTP 4.8 4.4~4.8 Mm
    4P STP 5.5 5.5 Mm
    2P STP 4.8 4.8 Mm
  • Cable CAT-5
    Descriptions
    -Can be used as local area network cable.
    -Construction: UTP 24AWG(7/0.205*4P)~(1)stranded wire
    or 24AWG(1/0.517*4P)~(2)solid wire. STP26AWG(7/0.165*4P+4P+Mylar+DW+AL/MY)
    or 24AWG(7/0.205*4P+MY+DW+AL/MY)
    Characteristics
    Jacket OD
    Pair NO Patch Core LAN Cable Unit
    4P UTP 5.5 5.2~5.5 Mm
    2P UTP 4.8 4.4~4.8 Mm
    4P STP 5.5 5.5 Mm
    2P STP 4.8 4.8 Mm
  • UL1007 PVC Hook up wire
    PVC Insulated Hook-up Wire

    Descriptions
    -UL Style1007, CSA AWM IA
    -Maximum Temperature Rating: 80 degree
    -Maximum Voltage Rating: 300V
    -Referenced Standard: UL758, UL1581
    -File No: E170689, LL109915
    -Solid or stranded, tinned or bare copper conductor, 32-16AWG
    -Color-coded PVC insulation
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 1007 E170689 VW-1 80 degree 300V () AWG XINYA-
  • HDMI Cable
    High Definition Multimedia Interface Electronic Cable
    Descriptions
    -UL Style20276, CSA AWM IA
    -Maximum Temperature Rating: 80癈
    -Maximum Voltage Rating: 30V
    -Referenced Standard: UL758, UL1581
    -File No: E170689, LL109915
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 20276 E170689 VW-1 80癈 30V XINYA-B LM HDMI CABLE

    Applications
    -Used for Digital TV, DVD player, Set-top box and oth
  • Sell DC Plug
    DC Cord Sets for Mobile Chargers
  • Wire Harness For Power
    1,The wire harness is used on any appliance,machine,equipment.
    2,100% tested before shipment.
    3,The wires are UL,CSA,CCC or VDE certificated.
    4,The connectors could be AMP, Molex, JST or other suppliers as the requirements
    of customers.
    5,RoHS compliant,ETC.
  • DVI Cable
    Digital Video Interface Electronic Cable
    Descriptions
    -UL Style20276, CSA AWM IA
    -Maximum Temperature Rating: 80癈
    -Maximum Voltage Rating: 30V
    -Referenced Standard: UL758, UL1581
    -File No: E170689, LL109915
    -Passes UL VW-1, CSA FT1 flame test

    Marking
    AWM 20276 E170689 VW-1 80癈 30V XINYA-B LM DVI CABLE

    Applications
    -Used for Digital TV, DVD player, Set-top box and other audio/vide
 
Page 1 of 1