Home > Product Catalog

Xetra Electric Co.,Ltd China

 
  • MCB Type Surge Protective Devices



    MCB Type Surge Protective Devices
    Code - BY2

    Rated Volt.: AC 50/60 Hz,380V
    It protects the electric network caused by the thunder or over voltage .
    Pole: 1Pole, 2Pole,3Pole, 4Pole
    Maximum continuous operating voltage : Uc 75 150 275 320 385 440 660V~
    Test grade:II
    Voltage protect level: Up< 350 550 1000 1250 1500 1750 2500V
    Maximum discharge current : (8/20uS) Imax 40kA
  • MCB Type Surge Protective Devices
    MCB Type Surge Protective Devices
    Code - BY1

    Rated Volt.: AC 50/60 Hz,380V
    It protects the electric network caused by the thunder or over voltage .
    Pole: 1Pole, 2Pole,3Pole, 4Pole
    Maximum continuous operating voltage : Uc 75 150 275 320 385 440 660V~
    Test grade:II
    Voltage protect level: Up< 350 550 1000 1250 1500 1750 2500V
    Maximum discharge current : (8/20uS) Imax 40kA
    Nominal d
  • H.R.C FUSE
    Low Volt. H.R.C Fuse
    Code - FB26D
    Technical Standard:IEC60269

    Fuse Protection:against overload or short circuit in Power System.
    Rated Insulation Volt: up to 550V
    Rated Heating Current: 32A, 63A
    Pole: 1Pole, 2Pole, 3Pole
    Fuse link Type: D02
    Fuse Holder Type: RL8
    Heigh (With handle) : 92mm
    Total Length: 93mm
    Installation: DIN Rail Type
  • H.R.C Fuse and its holder
    Low Volt. H.R.C Fuse and its holder
    Code - RT14
    Technical Standard:IEC60269

    Fuse Protection:against overload or short circuit in Power System and also Motor short circuit protetion special.
    Technical Standard:IEC60269
    Rated Insulation Volt: up to 550V, 50/60HZ
    Pole: 2Pole, 4Pole
    Rated Current(In):From 2A up to 1250A
    Quotation for:
    RT14-20,RT14-32,RT14-63 available
  • AC CONTACTOR
    CJX1(3TB 3TF)series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9~475A under AC-3 duty.It is mainly used for making/breaking electric circuits at a long distance & for frequent starting/stopping & with thermal relay to compose a magnetic motor starter,so.The products acoords with such standards as IEC60947-4-1 & GB14048.4.
  • Cast Resin Potential Transformer
    Material: Epoxy Cast Resin
    Rated Insulation Voltage: 11KV
    Rated insulation level:12/42/75kV
    Rated secondary Volt:110V
    surface creepage distance: class II
    Products accordance with: GB1207-1997 "Voltage transformer"
    Power factor of load:COS@=0.8 (lagging)
    Equipping with fuse: XRNPG-12/0.5A
  • Current Transformer
    Material: Epoxy Cast Resin
    Rated insulation level:12/42/75kV
    The power factor of burden:0.8(lag)
    Rated secondary current:5A/1A;
    Standard of secondary class filthy
    Performance conforms wite IEC standard and GB1208-97"Current Tansformer"
    Meter rage class safeguard sytem:Fs<11
  • Residual Current Circuit Breaker
    AC:240(220V)/415V(380V) 50/60HZ
    Pole: 2Pole, 4Pole
    Rated Current(In):
    6/10/16/25/32/40/50/63A
    Rated residual operating current:
    ( Irn) 30/50/75/100/300mA
    Rated residual non-operation Current:
    ( Irno) 0.5Irn (Below)
    Residual operating current scope: 0.5Irn~Irn
    Residual current off-time: <0.1s
    Ultimate short-circuit breaking capacity: (Inc) 6000A
    Endurance Times (More Over): 4000
  • Mini Circuit Breaker
    Features: Cut off phase wire and neutral wire at once and one time.
    AC:240V/ 50/60HZ
    Pole: 1Pole+N
    For overload and short circuit protection
    Standard:conforms to IEC60898
    Rated current: 6, 10, 16, 20, 25, 32A
    No. Of Pole: 1P+N
    Breaking capacity: 3000A
    Mechanical life: 20000
 
Page 1 of 1
Go to Page
Cannot find what you're looking for? Post a buying lead.