  • H.R.C FUSE
    Low Volt. H.R.C Fuse
    Code - FB26D
    Technical Standard:IEC60269

    Fuse Protection:against overload or short circuit in Power System.
    Rated Insulation Volt: up to 550V
    Rated Heating Current: 32A, 63A
    Pole: 1Pole, 2Pole, 3Pole
    Fuse link Type: D02
    Fuse Holder Type: RL8
    Heigh (With handle) : 92mm
    Total Length: 93mm
    Installation: DIN Rail Type
  • H.R.C FUSE
    Low Volt. H.R.C Fuse
    Code - FB26D
    Technical Standard:IEC60269

    Fuse Protection:against overload or short circuit in Power System.
    Rated Insulation Volt: up to 550V
    Rated Heating Current: 32A, 63A
    Pole: 1Pole, 2Pole, 3Pole
    Fuse link Type: D02
    Fuse Holder Type: RL8
    Heigh (With handle) : 92mm
    Total Length: 93mm
    Installation: DIN Rail Type
  • Current Transformer
    Material: Epoxy Cast Resin
    Rated insulation level:12/42/75kV
    The power factor of burden:0.8(lag)
    Rated secondary current:5A/1A;
    Standard of secondary class filthy
    Performance conforms wite IEC standard and GB1208-97"Current Tansformer"
    Meter rage class safeguard sytem:Fs<11
  • AC CONTACTOR
    CJX1(3TB 3TF)series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9~475A under AC-3 duty.It is mainly used for making/breaking electric circuits at a long distance & for frequent starting/stopping & with thermal relay to compose a magnetic motor starter,so.The products acoords with such standards as IEC60947-4-1 & GB14048.4.
  • Cast Resin Potential Transformer
    Material: Epoxy Cast Resin
    Rated Insulation Voltage: 11KV
    Rated insulation level:12/42/75kV
    Rated secondary Volt:110V
    surface creepage distance: class II
    Products accordance with: GB1207-1997 "Voltage transformer"
    Power factor of load:COS@=0.8 (lagging)
    Equipping with fuse: XRNPG-12/0.5A
  • Cast Resin Potential Transformer
    Material: Epoxy Cast Resin
    Rated Insulation Voltage: 11KV
    Rated insulation level:12/42/75kV
    Rated secondary Volt:110V
    surface creepage distance: class II
    Products accordance with: GB1207-1997 "Voltage transformer"
    Power factor of load:COS@=0.8 (lagging)
    Equipping with fuse: XRNPG-12/0.5A
  • AC CONTACTOR
    CJX1(3TB 3TF)series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 1000V,rated operation current 9~475A under AC-3 duty.It is mainly used for making/breaking electric circuits at a long distance & for frequent starting/stopping & with thermal relay to compose a magnetic motor starter,so.The products acoords with such standards as IEC60947-4-1 & GB14048.4.
  • Moulded Case Circuit Breaker
    The XEM1 Series molded case circuit breaker are similar as ABB Tmax type
    Series which you referenced.
    XEM1 series molded case circuit breaker is suitable for circuit of AC 50Hz/60Hz with rated voltage up to AC 690V
    and rated operating current to 630A. It features normal structure, reliable performance, complete accessories
    and high breaking capacity, used for power distribution and protecti
  • Mini Circuit Breaker
    Features: Cut off phase wire and neutral wire at once and one time.
    AC:240V/ 50/60HZ
    Pole: 1Pole+N
    For overload and short circuit protection
    Standard:conforms to IEC60898
    Rated current: 6, 10, 16, 20, 25, 32A
    No. Of Pole: 1P+N
    Breaking capacity: 3000A
    Mechanical life: 20000
  • Residual Current Circuit Breaker
    AC:240(220V)/415V(380V) 50/60HZ
    Pole: 2Pole, 4Pole
    Rated Current(In):
    6/10/16/25/32/40/50/63A
    Rated residual operating current:
    ( Irn) 30/50/75/100/300mA
    Rated residual non-operation Current:
    ( Irno) 0.5Irn (Below)
    Residual operating current scope: 0.5Irn~Irn
    Residual current off-time: <0.1s
    Ultimate short-circuit breaking capacity: (Inc) 6000A
    Endurance Times (More Over): 4000
 