Drop Out Fuse
Drop Out Fuse products from over 22 Drop Out Fuse manufacturers, exporters, suppliers and Drop Out Fuse wholesalers products directory.
-
Outdoor Drop Out Fuse Cut Out ((33KV) PEP-22)
Product Description
Outdoor Dropout Fuse Cutout (33KV) PEP-22
Outdoor Drop Out Fuse is implied to power system with voltage 
-
Outdoor Drop Out Fuse Cut Out (15-24KV) PEP-15
Outdoor Drop Out Fuse Cut Out (15-24KV) PEP-15
Outdoor Dropout Fuse cutout is implied to power system with voltage being 35kv 
-
Outdoor Drop Out Fuse Cut Out PEP-24
Outdoor Drop Out Fuse Cut Out PEP-24
Outdoor Dropout Fuse cutout is implied to power system with voltage being 35kv or lower a 
-
Outdoor Drop Out Fuse Cut Out (PEP-23)
Outdoor Drop Out Fuse Cut Out PEP-23
Outdoor Dropout Fuse cutout PEP-23
Technical specification:
Rated voltage: 33KV-35KV 
-
Fuse Cutout
Fuse Cutout, Cutout Fuse Specifications are as followings:Rated voltage: 12KV-15KV
Rated current: 100A/200A
Breaking current: 10KA-12KA
Impulse voltage: 110KV
Power frequency withstand 
-
High Voltage Falling Type Fuse
High voltage falling type fuseTypeRated voltage KVRated current ABreaking current voltage KAImpulse voltage BLLPower –frequency withstand UCrawling distance 
-
Fuse Cutout (RW7-12/100A)
Requirement: Attitude: ≤1000-3000mTemperature: ≤40 degreeWind speed: ≤35m/sThe place must be no burn, explode and shockEnvironment pollution: Grade IVTechnical Parameter: Rateds voltage(KV): 12Rated 
-
Fuse Drop-Out (HPRW5-12/100A)
Made of H60 bronze
Die-casting
Surface polishing process
Sand blasting
Electroless silver plating process are available 
-
Fuse Cutout (RW3)
Made of H60 bronze, die-casting, surface polishing process, sand blasting, electroless silver plating process are available, please contact us today! 
-
high voltage cutout fuse
Requirement: Attitude: ≤1000-3000mTemperature: ≤40 degreeWind speed: ≤35m/sThe place must be no burn, explode and shockEnvironment pollution: Grade IV
Technical Parameter: Rateds voltage(KV): 
-
-
Fuse Drop-Out (HPRW5-12/100A)
Requirement:
1) Attitude: ≤1000-3000m
2) Temperature: ≤40 degree
3) Wind speed: ≤35m/s
4) The place must be no burn, explode and shock
5) Environment pollution: Grade IVTechnical 
-
Fuse Drop-Out Accessories
Made of H60 bronze ,
Die-casting,surface polishing process,sand blasting,electroless silver plating process are available,please contact us today! 
-
Fuse Cutout (PRW10-12F)
Requirement: Attitude: ≤1000-3000mTemperature: ≤40 degreeWind speed: ≤35m/sThe place must be no burn, explode and shockEnvironment pollution: Grade IV
Technical Parameter: Rateds voltage(KV): 
-
Cutout Fuse (PRW12-12F/100A)
Requirement:
1) Attitude: ≤1000-3000m
2) Temperature: ≤40 degree
3) Wind speed: ≤35m/s
4) The place must be no burn, explode and shock.
5) Environment pollution: Grade IVTechnical 
-
High Voltage Drop-Out Fuse
Requirement: Attitude: ≤1000-3000mTemperature: ≤40 degreeWind speed: ≤35m/sThe place must be no burn, explode and shockEnvironment pollution: Grade IV
Technical Parameter: Rateds voltage(KV): 
-
Fuse Cutout (HPRWG1-12/100A)
Requirement: Attitude: ≤1000-3000mTemperature: ≤40 degreeWind speed: ≤35m/sThe place must be no burn, explode and shockEnvironment pollution: Grade IVTechnical Parameter: Rateds voltage(KV): 12Rated 
-
Drop-out Fuse With Load
Drop-out Fuse With Load (here in after abbreviated as ”Fuse”) is used in power distribution and distribution transformer with alternative current 50Hz, rated voltage 10kV for overload and short 
-
Cut Out Fuse, Drop Out Fuse (Polymer insulator with casting compositive)
1) Rated voltage: 10-36KV2) Rated current: 100A/200A 3) Breaking current: 10,000/12000A 4) Breaking voltage: 125-170kV5) Power frequency withstand voltage: 45-75kV6) Leakage distance: 250-720mm7) 
-
Cut Out Fuse, Drop Out Fuse, Fuse Cutouts, Fuse Link, Lightning Arrester
1) Rated voltage: 10-36KV2) Rated current: 100A/200A 3) Breaking current: 10,000/12000A 4) Breaking voltage: 125-170kV5) Power frequency withstand voltage: 45-75kV6) Leakage distance: 250-720mm7) 
-
Fuse Cutout
Drop-out Fuse cutouts and load switching fuse cutouts are for outdoor used high voltage protective device .To be connected with in coming feeder of distributing transformer or distribution lines it... 