flow meter

Detailed Product Description

LZ-B type probe remote transmission metal tubular rote meter
 LZ-B type metal tube rote meter can be substituted for importing type H27. It has simple structure, reliable, suitable to wide range of temperature, high accuracy. This type of flow meters has local display, electric remote control, and anticorrosion and explosion types. They are widely used for liquid and air flow measurement and control automatically in lines of national protection, chemical, petroleum, metallurgy, electric power, pro-environment, medical, textile. The area of transducer can adopt materials of stainless steel (1Cr18Ni12MO2Ti),OCr18Ni12MO2Ti and inside liner fluoroplastic to adapt to level measurement of anticorrosion fluid, such as chlorine air, salt water, hydrofluoric acid, nitric acid and sulphuric acid.
Electric remote transmission meter can output standard signal, and can match with complex meter and computer to realize comprehensible control.
Principle and structure
When the up-flow fluid goes through measuring tube with perforate plate, taper floater floats upward. The height of moving represents flow value, and transmit to indicator through couple connecting of magnetic steel in floater and magnetic steel in indicator. And that causes the point turnover, lobe plate make pointer indicate the flow value linearly.
2) Technique parameter (as form 1)
Proportion of maximum Value to min. value: 10:1
Accuracy class: 1.5, 2.5
Operate pressure: 1.5, 2.5, 4.0, 6.4MPa
Fluid temperature: -80~+300℃(inside lined with fluoroplastic flow meter0~+80℃)
Environment temperature: -20~+50℃
Liquid medium viscosity:Φ15〈 5MPa.S(1MPa.S=1CP)
                      Φ25~Φ100<250 MPa.S
Connection: flangeJB81.82-59
Total height: 250mm
3), installing size (as form 2)
4), electric feature:
Signal output: three-wire system, four-wire system, two-wire system
Linearity: ±1%
Electric source: 24VDC+10% -15%
Current consumption: ~28mA
Load resistance: 0~10Madc 0~1kΩ
               4~20ADC 150~350Ω
Environment temperature: -25~+55℃
Explosion-proof: ExibⅡCT5
5) magnetic filter:
If there is magnetic particulars in the fluid to be measured, magnetic filter should be added to flow meters inflow point. Magnetic filter has installed few of high strength magnetism poles rowed in helix (reduce pressure loss). The magnetic pole outside is packaged with UPVC to protect the magnetic pole be corroded.