Detailed Product Description

Programming.

 *Press Key # four times, the Buzzer make long sound BI, POWER (Red), OK (Green), Mode (Yellow) is on at the same time.

*Input 5 digits PIN (Default Password is 12345), OK (Green) is off. The machine enters Making Program Status.

*Press key 2, MODE light (Yellow) is on, POWER (Red) and OK (Green) light are off.

*Input 4 character password to open a door (Such as: 0008), the POWER (Red) and OK light (Green) flash.

*Read the user card that needs log in, a sound BI will be heard, POWER light (Red) is off, OK (Green) and MODE light (Orange) are on, the user card is registered successfully.

*Input 4 digits PIN for opening the door, OK (Green) is off, POWER (Red) is on, which showing PIN is registered.

*Press Key 6 to Exit programming status.

 Other Setting:

Change Program Operating Password

*Press key 1, The MODE (Yellow) light is on, POWER (Red), OK (Green) light is off.

*Input PIN as your will (Example, 23456), the Buzzer make a short sound of BI, OK (Green) is on, POWER (Red), MODE (yellow) is on, PIN has changed successfully.  Note: The PIN should be kept; you will need it to enter the Making Program Mode next time. If PIN forgotten, please execute Machine Initial Step.

 Delete the single user card

*Press key 3, MODE light (yellow) is bright, POWER (Red) and OK (green) light are off.

*Input 4 character user series No that needs to be deleted. (Series No on card, such as: 0008), a sound BI will be heard. This means the deletion is successful.

 

Delete all registered cards

*Press key 4, BI will be heard twice. All the registered cards and passwords are deleted.

 

Open Door Time Setting

*Press key 5, MODE light (Yellow) is bright, POWER (Red) and OK (Green) are off.

*Input 2 character as the door open time (Such as: 05, means that the door open time is 5 second), sound BI will be heard twice, this means the door open time setup is successful.

 Note: The default open time is 3 second

 

 

Related Products from Other Manufactures

  • sell CCTV with saucer camera by Shenzhen Sipo Technology Co., Ltd. china
    Licence verified member
  • CCTV day & night camera by Shenzhen Sipo Technology Co., Ltd. china
    Licence verified member
  • sell video door phone with metal housing by Shenzhen Sipo Technology Co., Ltd. china
    Licence verified member
  • sell video door phone with CCD or CMOS camera by Shenzhen Sipo Technology Co., Ltd. china
    Licence verified member
  • EAS Label by Zhejiang Kahn Electronics Co., Ltd. china
    Licence verified member

Related Manufacturers

Send Message