Huiqitong Electronic Co., Ltd. > Selling Leads > E2002-D Keyboard Reader/Controller

Member Since

2008

Huiqitong Electronic Co., Ltd.

E2002-D Keyboard Reader/Controller

Detailed Product Description

Wire Connection

Red line: +12V

Black line: GND

Orange line + Block line: Switch

Blue line (+) + Black line (-): Electricity lock

Yellow line: Empty

Black line: GND

Brown line + green line: Doorbell

 

Access control machine program method

 

1. Password Opening Door Mode.

*Press Key # four times, the Buzzer make long sound BI, POWER (Red), OK (Green), Mode (Yellow) is on at the same time.

*Input 5 digits PIN (Default Password is 12345), OK (Green) is off. The machine enters Making Program Status.

*Press key 2, MODE light (Yellow) is on, POWER (Red) and OK (Green) light are off.

*Input 5 digits password to open a door (Such as: 00008), the POWER (Red) and OK light (Green) flash.

*Press Key 6 to Exit programming status.

 

2. Other Setting

a. Change Default Programming Password

*Press key 1, The MODE (Yellow) light is on, POWER (Red), OK (Green) light is off.

*Input PIN as your will (Example, 23456), the Buzzer make a short sound of BI, OK (Green) is on, POWER (Red), MODE (yellow) is on, PIN has changed successfully. Press Key 6 to Exit. Note: The PIN should be kept; you will need it to enter the Making Program Mode next time. If PIN forgotten, please execute Machine Initial Step.

 

b. delete the single password

*Press key 3, MODE light (yellow) is bright, POWER (Red) and OK (green) light are off.

*Input 4 character user series No that needs to be deleted. (Series No on card, such as: 0008), a sound BI will be heard. This means the deletion is successful. Press Key 6 to Exit

 

c. Delete all passwords

*Press key 4, BI will be heard twice. All the registered passwords are deleted. Press Key 6 to Exit

 

d. Open Door Time Setting

*Press key 5, MODE light (Yellow) is bright, POWER (Red) and OK (Green) are off.

*Input 2 character as the door open time (Such as: 05, means that the door open time is 5 second), sound BI will be heard twice, this means the door open time setup is successful. Press Key 6 to Exit

 

 

 

 

Related Manufacturers

Send Message