Specifications
◇Battery can be detached.
◇ Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display.
◇ Battery: Rechargeable high-energy built-in battery
◇ Advanced streamline outline design, portable, compact, lightweight
◇ Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, etc.
◇ Easy operation with user friendly menu structure design and rotary dial
◇ Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating.
◇ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
◇ Optional built-in wireless networking function
◇ Support external printer to record graph and trend
◇ Intelligent audio and visual comprehensive alarm
◇ In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
◇ Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
◇ Battery: Rechargeable high-energy built-in battery
◇ Advanced streamline outline design, portable, compact, lightweight
◇ Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, etc.
◇ Easy operation with user friendly menu structure design and rotary dial
◇ Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating.
◇ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
◇ Optional built-in wireless networking function
◇ Support external printer to record graph and trend
◇ Intelligent audio and visual comprehensive alarm
◇ In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
◇ Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.
Optional configuration: Wireless connection, Recorder and ETCO2, 2-IBP
Technical Parameter
◆Non-invasive blood pressure |
◆Temperature | ||||
Measurement type: adult, pediatric, neonate |
Measurement range: 25 - 45 ℃ | ||||
Measurement
range: |
Systolic Diastolic Mean |
4.0 - 37.0 kPa 1.3 - 33.0 kPa 2.6 - 35.0 kPa |
Accuracy: ± 0.1 ℃ | ||
Accuracy : ± 0.4 kPa or 5 % |
Resolution: 0.1 ℃ | ||||
Resolution: 0.1 kPa |
response time: ≤ 3 min. | ||||
Protection: over pressure |
|||||
◆ECG |
◆Respiration Rate | ||||
Input: 5 wires ECG cable |
Measurement range: 0 - 120 BPM(adult) | ||||
Lead section: Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V |
Accuracy: ± 1 BPM or 5 % | ||||
Gain(mm/mV): 1/4,1/2,1,2,4 |
Resolution: 1 BPM | ||||
Frequency response: |
Diagnosis Monitor Surgery |
0.05 - 100Hz 0.5 - 40 Hz 1.0 - 25 Hz |
◆CO2 | ||
Sweep speed (mm/sec): 12.5, 25, 50 |
Measurement range: 0 %-10.0 %
(ins CO2 and et CO2) | ||||
Heart rate range: 30-254 BPM |
Accuracy: ± 2 mm Hg (< 5 %
Measurement value) | ||||
Heart rate accuracy: ± 1 % |
10 % (> 5 % Measurement value) | ||||
ST segment deviation analysis: -0.8-+0.8mV |
◆Pulse oximetry | ||||
ST accuracy: ±0.02mv |
SPO2 measurement range: 0 - 100 % | ||||
Invasive blood pressure |
Resolution: 1 % | ||||
Measurement range: 0~40kPa (0~300mmHg) |
pulse measurement range: 30- 254BPM | ||||
Channel: 2 channel |
Accuracy: ± 2 % | ||||
Transducer sensitivity: 5MV/V/mmHg |
Resolution: 1 BPM | ||||
Unit display: kPa or mmHg selectable |
|||||
◆Environment | |||||
◆Power requirements |
Operation |
Storage | |||
Input: 98~260 V AC, 50/60Hz |
Temperature |
0.5 - 40 ℃ |
-20 - 50 ℃ | ||
Consumption: ≤ 80VA |
Relative humidity |
≤ 80% |
≤ 90% |