ZHEJIANG DESHANG CHEMICAL TECH CO.,LTD
China Manufacturer with main products: Acrylic Resin, 2-HEMA, HpPA HEA, Carbon Steel Seamless Pipe |
Related products from verified members
Place of Origin: | Zhejiang in China |
---|
Specifications
Chinese Chemical Name: Acrylic Resin
Common name or trade name chemicals: Acrylic resin
English name of Chemicals: Acrylic Resin
Company Name: Zhejiang Deshang Chemical Technology Co., Ltd.
Zip: 311107 Fax :0572-8874188 Tel(Company Emergency) :0572-8434059
Technical manual coding: YW-AQ-001 Effective date :2003-09-10
National Emergency Telephone: 119,110,120
Mixture
Xylene 10∽15 1330-20-7
Butyl acetate 15∽25 123-86-4
MIBK 5 ~ 10 108-10-1
R100 5 ~ 10 64742-94-5
Environmental hazards:When the leak, waste, there may be impact on the environment, product and wash water can not be directly to the ground, rivers and drains discharge.
Explosion danger: flammable, its vapors can be stranded form explosive mixtures with air, open flame, heat a combustion explosion hazard.
Eye Contact: Immediately turn down the eyelids, flush with running water or saline for at least 15 minutes, medical, and hazardous material content to tell a doctor to receive good treatment.
Inhalation: rapidly from the scene to fresh air, warmth, keep the airway clear.Breathing difficulties, give oxygen.Such as respiratory and cardiac arrest, immediate resuscitation and heart massage.Medical treatment.Jiyong adrenaline.
Ingestion: drink enough warm water, induce vomiting (except with doctor's advice, not reluctantly or induce vomiting), seek medical care immediately.
Fire fighting methods and extinguishing agents: free foam, carbon dioxide, dry powder, sand saves, no water.
Removed as soon as possible surrounding combustibles.
Specified fire extinguishers.
Cooling water temperature environment in closed containers.
Fire activity on the outlet.
Fire against water.
Emergency treatment: cutting off sources of ignition.Rapid leak contaminated areas evacuated personnel to a safe area, and isolation and strict restrictions on access to personnel.Recommended emergency personnel wearing appropriate protective equipment, such as positive pressure self-contained breathing apparatus and wear protective clothing.Cut off the source of leakage as possible, to prevent access to sewers, flood discharge trench so restrictive space.
Small leak: using does not produce as much as possible the impact of static sparks spill recovery tool will collect leakage in a sealed container with sand, activated carbon or other inert material absorbing residue, can also be used non-flammable dispersantemulsion made of scrub, lotion diluted into the wastewater system.
Large leak: to build a causeway or trenching asylum, covered with foam to reduce vapor hazard.Spray water cooling and dilution steam to protect the scene.Explosion-proof pumps transfer to tankers or exclusive collector, recycling or shipped to handle waste disposal sites.
Operation Handling Precautions:
Operators must receive special training, strict compliance with operating rules.Proposed operators to wear self-absorption filter anti-virus Mask (half face mask), wearing protective chemical safety glasses, put poison penetrate clothing to wear, wear rubber gloves oil.Keep away from fire, heat, workplace smoking.Use explosion proof ventilation systems and equipment to prevent steam leakage to the .Workplace air.Avoid contact with oxidants, aerosol should pay attention to traffic (not more than 5m / s), and a grounding device To prevent accumulation of static electricity.When handling care, and to prevent damage to packaging and containers.Equipped to respond to the variety and number of emergency fire equipment and leak Processing equipment.Emergency rescue or evacuation, it is recommended to wear filter respirators (half-mask), empty containers may Harmful residues.
Storage Precautions: Store in a cool, ventilated warehouse, avoid direct sunlight.Away from fire and heat.Storage temperature should not exceed 30 ℃.Keep container away.Should oxidants, food and chemicals stored separately and avoid mixing reservoir.Use of explosion-proof lighting, ventilation.Prohibit the use of easy to produce sparks of mechanical equipment and tools.Storage areas should be equipped with spill response equipment and suitable host processing equipment.
Maximum allowable concentration: xylene: PC-TWA: 50 (mg/m3); PC-STEL: 100 (mg/m3);Toluene: PC-TWA: 50 (mg/m3); PC-STEL: 100 (mg/m3);Butyl acetate: PC-TWA: 200 (mg/m3); PC-STEL: 300 (mg/m3);Monitoring methods: gas chromatography.Project control: production process confined to enhance ventilation.Respiratory protection: air respirator should be worn or oxygen breathing apparatus.
Eye protection: Wear chemical safety glasses.
Body Protection: Wear impervious overalls antivirus, electrostatic coating, the wear anti-static anti-static clothing and shoes.
Hand protection: wear rubber gloves oil.
Other protection: work site prohibit smoking, eating and drinking, work to avoid drinking alcoholic beverages before.After work, take a shower.Conduct pre-employment and periodic medical examinations.
Appearance and character: colorless to colored transparent or turbid viscous liquid PH value: 3 ~ 7
Melting point (℃): density (g/m3): 1.05 ± 0.05 (20 ℃)
Boiling point (℃): 110 ~ 162 Flash point (℃): less than 23
Ignition Temperature (℃): 480 explosive limit% (V / V): 10.5
Explosive limit% (V / V): 1.1 Usage: Metal, plastic and wood surface coating
Stability: Stable.
Cut with material: strong oxidizers.
Avoid contact with the conditions: fire, heat.
Aggregate risk: does not occur.
Decomposition products: carbon monoxide, carbon dioxide.
Acute toxicity of D50 kg / mg (rat oral): 5019
Ecotoxicity: No information.
Ecological Degradation: No information.
Non-ecological degradation: No information.
Bioconcentration or bioaccumulation of: No information.
Waste characteristics: hazardous waste.
Waste Disposal Method: Treatment with controlled burning.
Waste Note: discarded containers, should be licensed to handle industrial waste disposal.Cleaning containers and equipment clean water, not directly into the ground and rivers.
Dangerous Goods Code: 32197
UN Number:
Packaging flag: flammable.
Packing Group: Ⅲ
Packaging: 18.5L or 200L drums.
Transportation Note: Summer should be sooner or later transport to prevent the sunlight exposure.Sure the container without leakage, to prevent the container flip, drop, damage, etc., transportation routes as required to exercise.
Dangerous chemicals Management Ordinance (March 15, 2002), that dangerous chemicals for production, management, storage, transport, use and disposal of hazardous chemicals and disposal and other provisions are made accordingly.
"Commonly used in the classification of dangerous chemicals and signs" (GB13690-92), designated as section 3.3 of its high flash point flammable liquid class.
"Dangerous goods classification and code" (GB6944-2005) to be designated dangerous goods number 33646.
"Type of transport of dangerous goods packaging principles" (GB/T15094-94), to classify it as [Ⅰ] packing.
The occupational health standards in the PRC, "the workplace hazards of occupational exposure limits" (GBZ 2-2002), "workplace hazardous exposure limits Part 1: Chemical Hazards" GBZ2.1-2007 provides access to dangerousallowable concentrations of chemicals.
References: 1, way to forest, "Solvent Handbook", Chemical Industry Press, 1994
2, Mobil product safety information circulars, Mobil R100.
Filling date:2008-09-01
Guidance Department: Zhejiang DESHANG Technical Inspection Department of Chemical Technology Co., Ltd..
Data Audit Unit: Zhejiang DESHANG Department of Chemical Technology Co., Ltd. technical review.
Edit Description:
Other information:
This manual is based on currently available data collected written in the.Risk related to this product, hazardous nature
Reporting and evaluation, is based on information derived from the raw material is not sufficient.Is used in accordance with the safe use of
The responsibility.
The manual production of chemicals from the the date, updated every five years, if the discovery of new dangers,
Information published in the six months, security technology will revise the contents of the specification.
Recorded content, with the amount of physical and chemical nature of the data has nothing to do with product quality.
Service Guarantee
-
Free Service Charge
ECVV doesn't charge any service fee to Buyers for buying this product.
-
ECVV Supply
ECVV is responsible for supply, and provides product quality inspection, fund supervision and supply chain services.
-
Product Quality Commitment
ECVV China Sourcing Agent will assess the reputation and supply ability of the factory and conduct field trips to select the high-quality Chinese factories for buyers.
-
Deposit Service Commitments
In order to improve the quality of service, ECVV will charge for a 100CNY deposit for the agent purchasing order, and the deposit will be part of subsequent purchasing costs.
After paying a deposit, if the purchasing order is not completed because of unsatisfied ECVV services, ECVV will refund your deposit.
Resin from this supplier
More products from other suppliers
Maintenance Resin Suppliers :
Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.
Learn More>> Start Safebuy Order