Principle of the CMS50D1 Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
■Small in volume, light in weight and convenient in carrying
■Operation of the product is simple ,low power consumption
■SpO2 value display
■Pulse rate value display, bar graph display
■Pulse waveform display
■The display mode can be changed
■Screen brightness can be changed
■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
■Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
■Display format can be saved after power off
Screen Resolution: 128*64
SpO2 Measuring Range: 0%~100%, (the resolution is 1%).
Accuracy: 70%~100%: ±2% ,Below 70% unspecified.
PR Measuring Range: 30bpm~250bpm, (the resolution is 1bpm)
Accuracy: ±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption: less than 30mA
Voltage: DC 3.0V
Power Supply:1.5V (AAA size) alkaline batteries × 2
Battery working hour: Theoretical number is 32 hours.
Safety Type:Interior Battery, BF Type
■A hanging rope
■A user manual
Dimension: 61(L) × 36(W) × 32(H) mm
Weight: About 60g (with the batteries)
Service Guarantee
-
Free Service Charge
ECVV doesn't charge any service fee to Buyers for buying this product.
-
ECVV Supply
ECVV is responsible for supply, and provides product quality inspection, fund supervision and supply chain services.
-
Product Quality Commitment
ECVV China Sourcing Agent will assess the reputation and supply ability of the factory and conduct field trips to select the high-quality Chinese factories for buyers.
-
Deposit Service Commitments
In order to improve the quality of service, ECVV will charge for a 100CNY deposit for the agent purchasing order, and the deposit will be part of subsequent purchasing costs.
After paying a deposit, if the purchasing order is not completed because of unsatisfied ECVV services, ECVV will refund your deposit.
Oximeter Fingertip from this supplier
More products from other suppliers
Maintenance Oximeter Fingertip Suppliers :
Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.
Learn More>> Start Safebuy Order