SHENZHEN SHOWAY ENTERPRISES SERVICE CO.,LTD| Sourcing Services

SHENZHEN SHOWAY ENTERPRISES SERVICE CO.,LTD

[ Guangdong, China ]
Business Type: Sourcing Services
Brand(s): SHOWAY
Main Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Main Product: Intrusion Alarms, Dvr, Sensors, CCTV Cameras, Video/Audio Intercom, Access Control Products and Other Security and Electronic Products, Fire Alarms, Networking Project Accessories
Year Established: 2009
Factory Location: F/7, Building76, NanYuan, Minzhi St., Shenzhen, China
Ownership Type: LLC (Ltd Liability Corp)
Employ Number: 51 - 100 People
Export Percentage: 81% - 90%
QA/QC: In House
  • Onsite operations checked and legal status confirmed
SHENZHEN SHOWAY ENTERPRISES SERVICE CO.,LTD

China Manufacturer with main products: Intrusion Alarms, Dvr, Sensors, CCTV Cameras, Video/Audio Intercom, Access Control Products and Other Security and Electronic Products, Fire...

12th
Home  >Products Catalog > Fire Alarms > Conventional Fire Alarm Control Panel

Conventional Fire Alarm Control Panel SafeBuy Supplier Member

Payment Terms: T/T, Western Union
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Place of Origin: Guangdong in China

Specifications

CJ-F 1000 Series Conventional Fire Alarm Control Panel
 
Model: CJ-F1004, CJ-F1008, CJ-F1016
 
The CJ-F1000 Series Conventional Fire Alarm Control Panel is a 24 volt, four, eight, sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective CJ-F1000 Series can be used in a variety of low- to mid-sized applications.
 
FEATURES                                                                                                                                                                         
Four to Sixteen Style B (Class B) Initiating Device Circuits (IDCs).
All zones accept two-wire smoke detectors and any normally-open contact devices.
Zones 1 - 16 configured as general alarm zones.
All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology.
Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs).
NACs may be programmed:
Silenceable.
Non-Silenceable.
Auto-Silence (program 5 to 20 minutes).
1.25 amps of NAC power.
3.0 amps of total system power.
Alarm, Trouble and Supervisory, relay output.
24-volt operation.
Resettable four-wire smoke detector power @ 500 mA.
Non-resettable power @ 500 mA.
Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent).
Disable/Enable control per IDC.
Reverse polarity protection.
Control buttons:
Mode
Test
ACK (Acknowledge) Alarm Silence
Reset
LED indicators:
AC Power(green & yellow LED)
Fire Alarm(red LED)
Trouble(yellow LED)
Supervisory(yellow LED)
Signal Silence(yellow LED)
Battery Power(green & yellow LED)
Zone Disable(yellow LED)
NAC Fault(yellow LED)
NAC Disable(yellow LED)
Zone Alarm(one for each zone) (red LED)
Zone Trouble(one for each zone) (yellow LED)
Earth Fault (on circuit board)
Battery Fault (on circuit board)
Charger Fault (on circuit board)
 
SPECIFICATIONS                                                                                                                                                             
AC POWER
90~270 VAC, 50 Hz, 2.0 amps.
Wire size: minimum 14 AWG (2.0 mm2) with 600-volt insulation.
BATTERY
Sealed lead-acid batteries only.
Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge.
Maximum battery charger capacity: 18AH battery.
NOTE: two 4AH batteries can be housed in the cabinet. Larger
batteries require a separate battery box.
Total 24 V system power: 3.0 amps.
Notification appliance (signal) power: 2.5 amps.
Maximum current per NAC: 1.25 amps (expandable to 2.5amps).
Maximum battery charging capability: 18 AH.
Auxiliary Outputs
Resettable four-wire smoke detector power @ 500 mA.
Non-resettable power @ 500 mA.
NOTE: Total current for auxiliary power outputs and two NACs must not exceed 3.0 amps. .
Integral Form-C Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30VAC (resistive).
 
CABINET AND MOUNTING
CABINET PHYSICAL DIMENSIONS: 40.0 cm high x 35.0 cm wide x 11.5 cm deep.
CARTON PACKAGE DIMENSIONS: 48.0 cm high x 42.0 cm wide x 18.5 cm deep.
CABINET NET WEIGH: 6.0 Kg. (without batteries).
CABINET GROSS WEIGH: 6.6 Kg. (without batteries).
MOUNTING: The cabinet mounts using two key slots at the top of the back and two additional 6.5mm diameter holes at the bottom.
 

 

Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.

Learn More>> Start Safebuy Order

Communicate with Supplier

Ms. Alice
Join ECVV community
Join Facebook Group

You May Like

No desirable products? View More