Contec Medical System Co., Ltd.

China Manufacturer with main products: Patient Monitor, Fetal Doppler, Pulse Oximeter, Baby Doppler, Baby Monitor, Pulse Oxymeter, ECG, Stethoscope, Ultrasound Scanner

Home  >Products Catalog > Others > Multi-Parameter Patinet Simulator

Multi-Parameter Patinet Simulator

Payment Terms: T/T, Paypal, Western Union
Update Time: 2012/6/20

Related products from verified members

Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Place of Origin: Hebei in China
Packaging Details: Carton

Specifications

Multi-Parameter Patinet Simulator

MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement. It can check the monitor rapidly near the bed, also can test the quality warranty of ECG equipment, monitor and remote therapy equipment, At the same time, it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
■3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
■Display the output waveforms synchronously, which is convenient for user to  
 compare with the   test equipment.
■It integrates the functions of SD socket interface, user can output the
  custom waveform by this   device.
■Built-in templates list to provide the waveform that is expressed by each 
 preset sequence   number,which is convenient for searching.
■Two operation interfaces:Chinese and English.
■Operate with keystroke and touch-screen expediently and rapidly.
■Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
■Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
ECG/Arrhythmia
ECG

■Conventional: All leads have the same voltage with the II-lead as the reference
■Amplitude: 0.5,1.0,1.5 and 2.0mV
■The accuracy of Amplitude: ±2%
■ECG Rate:
 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340      and 350 BPM
■ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
■The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
■The default: 80 BPM,1mV
Arrhythmia
■Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia,
 Missed Beat, Atrial
■Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
■Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular
  Contraction (PVC) 6/min,
■PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired 
  PVCs, Run 5
■PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
■Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left 
 Ventricular Focus
■PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early
  Right
■Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right 
 Ventricular Focus, Multifocal PVC
■Conduction Defects: First Degree Heart Block, Second Degree Heart Block,
  Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch
  Block  
ECG Performance Testing
■ECG amplitude: 0.5,1.0,1.5 and 2.0mV
■The accuracy of Amplitude: ±2%
■Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
■Square: 0.125 and 2.0 Hz
■Triangle: 2.0 and 2.5 Hz
■Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
■ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 
 260, 280, 300,   320, 340 and 350 BPM
■The accuracy of ECG Rate: ±1%
Respiration
■Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN
■Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
■Baseline Impedance:500,1000,1500 and 2000
■Apnea: 12 s, 22 s, 32 s
■ECG simulator with adjustable heart rate/12-lead output
■33 kinds of Arrhythmia waveforms
■Pacemaker 
■Two IBP channels
■Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32
  seconds.
■Standard ECG calibration
■Export square,triangle and sine with adjustable frequency
IBP
■The default: 00/00mmHg
■Dynamic IBP
Channel 1: Artery  120/80mmHg
               Radial 120/80mmHg
               Left Ventricle 120/00mmHg
               Right Ventricle 25/00mmHg
Channel 2: Artery  120/80mmHg
               Radial 120/80mmHg
               Left Ventricle 120/00mmHg
               Right Atrium 15/10mmHg
               Right Ventricle 25/00mmHg
               Pulmonary Artery 25/10mmHg
               Left Atrium 14/4mmHg
Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg 

Service Process

Service Guarantee

  • Free Service Charge

    ECVV doesn't charge any service fee to Buyers for buying this product.

  • ECVV Supply

    ECVV is responsible for supply, and provides product quality inspection, fund supervision and supply chain services.

  • Product Quality Commitment

    ECVV China Sourcing Agent will assess the reputation and supply ability of the factory and conduct field trips to select the high-quality Chinese factories for buyers.

  • Deposit Service Commitments

    In order to improve the quality of service, ECVV will charge for a 100CNY deposit for the agent purchasing order, and the deposit will be part of subsequent purchasing costs.

    After paying a deposit, if the purchasing order is not completed because of unsatisfied ECVV services, ECVV will refund your deposit.

Simulator from this supplier

More products from other suppliers

Dilator    
Elevating Chair    
Min Order: 1 Piece
Stainless steel medicine chest    
FOB Price:
Min Order: 0 Set
Cryostat    
FOB Price: 600.00-2000.00 USD/Piece
Min Order: 1 Piece

Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.

Learn More>> Start Safebuy Order

Communicate with Supplier

Ms. Ivy Wang