Tsingtao Toky Instruments Co., Ltd.
China Manufacturer with main products: Wood Moisture Meter, Textile Moisture Meter, Concrete Moisture Meter, Food Moisture Meter, Paper Moisture Meter, Grain Moisture Meter,... |
Multi-Parameter Water Quality Meter BT900
FOB Price: | 1.00 - 100.00 USD/Piece |
---|---|
Payment Terms: | T/T, Paypal, Western Union |
Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Shandong in China |
Packaging Details: | Parcel |
Specifications
water quality parameters, including pH, ORP, Ion, Conductivity
Automatic Temperature Compensation ensures high accuracy
Calibration due reminder helps you to calibrate meter regularly.
Automatic endpoint function freezes stable measured values.
Help message as a operational guide to helps you understand
Setup menu lets user customize the calibration points, stability
conditions, date and time to meet measurement requirements.
Expanded memory stores and recalls up to 500 readings.
pH Mode:
During the pH mode, Up to 5 points push-button calibration with auto-
buffer recognition.
Selectable pH buffer standards and resolution (0.1, 0.01, 0.001pH).
Automatically calculates and displays electrode slope that helps you
decide whether to replace pH electrode.
ORP Mode:
Single point offset calibration allows user adjusts displayed value to
a known standard.
Absolute or Relative mV measurements provides accurate readings.
Ion Mode:
Standard BNC connector can connects many Ion Selective Electrode.
2 to 5 points push-button calibration from low to high concentrations. Selectable multiple concentration units, including ppm, mg/L, mol/L. Direct readout ion concentration simplifies measurement process. mV measurement allows user to check performance of ion electrode.
Conductivity Mode:
Up to 5-point push-button calibration allows user to uses customized
calibration solutions.
Adjustable TDS factors, cell constants, temperature coefficients and
normalization temperature (20°C or 25°C).
Selectable linear or pure water compensation modes.
In salinity measurement modes, selectable practical salinity (PSU) or
seawater measurement standard (ppt).
Dissolved Oxygen Mode:
1 or 2 points auto-calibration (100% in saturated air or air-saturated
water, 0% in zero oxygen solution).
Manual salinity and barometric pressure compensation.
Selectable readout in ppm, mg/L or % saturation.
|
||||||
Specifications: | ||||||
Model | Bante900 | |||||
pH Range | -2.000~20.000pH | |||||
pH Accuracy | ±0.002pH | |||||
Resolution | 0.001, 0.01, 0.1pH, Selectable | |||||
Calibration Points | Up to 5 points | |||||
Calibration Solutions | USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/ 12.75) | |||||
Ion Concentration Range | 0.001~19999ppm, mg/L, mol/L (Depending on measuring range of Ion Selective Electrode) | |||||
Ion Concentration Accuracy | ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent) | |||||
Calibration Points | 2 to 5 points | |||||
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm | |||||
mV Range | -1999.9~1999.9mV | |||||
mV Accuracy | ±0.2mV | |||||
Resolution | 0.1, 1mV, Selectable | |||||
Conductivity Range | 0~20mS/cm (Max.200mS/cm) | |||||
Conductivity Accuracy | ±0.5% Full Scale | |||||
Calibration Points | Up to 5 points | |||||
Calibration Solutions | 10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm | |||||
TDS Range | 0~10ppt (Max. 20ppt, Depending on factor setting) | |||||
TDS Accuracy | ±1% Full Scale | |||||
TDS Factor | 0.1~1.0 (Default 0.5) | |||||
Salinity Range | 0~10ppt (Max.80ppt) | |||||
Salinity Accuracy | ±1% Full Scale | |||||
Salinity Measurement Modes | Practical Salinity (PSU) or Seawater Measurement Standard (ppt) | |||||
Resistivity Range | 0~100MΩ | |||||
Resistivity Accuracy | ±1% Full Scale | |||||
Resolution | 0.001, 0.01, 0.1, 1, Automatic | |||||
Temperature Coefficient | 0.0~10.0% per °C | |||||
Compensation Modes | Linear or Pure Water | |||||
Cell Constant | K=0.1, 1, 10, Selectable | |||||
Normalization Temperature | 20°C or 25°C | |||||
Dissolved Oxygen Range | 0.00~20.00mg/L or ppm | |||||
Resolution | 0.01mg/L | |||||
Dissolved Oxygen Accuracy | ±0.2mg/L | |||||
% Saturation of Oxygen | 0.0~200.0% | |||||
Accuracy | ±2.0% | |||||
Salinity Correction | 0~50g/L | |||||
Pressure Correction | 60.0~112.5kPa, 450~850mmHg | |||||
Temperature Range | 0~105°C, 32~221°F | |||||
Temperature Accuracy | ±0.5°C, ±0.9°F | |||||
Temperature Calibration | Manual | |||||
Temperature Compensation | 0~100°C, 32~212°F, Automatic or Manual; DO Mode: 0~50°C, 32~122°F, Automatic | |||||
Auto-Off | Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable) | |||||
Hold Function | Manual or Automatic endpoint | |||||
Stability Conditions | Low or High, Selectable | |||||
Calibration due reminder | 1 to 30 days or Off | |||||
Reset Function | Yes | |||||
Memory | 500 data sets with Date/Time stamping | |||||
Output | USB Communication Interface | |||||
Connector | BNC and 6-pin connector | |||||
LCD Display | Custom dual-display LCD (130×110mm) | |||||
Power Requirements | DC5V, using AC adapters, 220VAC/50Hz | |||||
Dimensions | 210(L)×188(W)×60(H)mm | |||||
Weight | 1.2kg |
More products from other suppliers
Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.
Learn More>> Start Safebuy Order