Tsingtao Toky Instruments Co., Ltd.| Manufacturer

Tsingtao Toky Instruments Co., Ltd.

[ Shandong, China ]
Business Type: Manufacturer
Brand(s): TOKY INSTRUMENTS
Main Markets: Eastern Europe, Southeast Asia, Oceania, Mid East, Western Europe
Main Customer: Plant
Main Product: Wood Moisture Meter, Textile Moisture Meter, Concrete Moisture Meter, Food Moisture Meter, Paper Moisture Meter, Grain Moisture Meter, Ultrasonic Thickness Gauge, Humidity Meter
Year Established: 2010
Legal Representative: Liu Jinfeng
Factory Location: Qingdao
Years OEM Experience: 3
Production Line Count: 3
Ownership Type: Partnership
Employ Number: 11 - 50 People
Annual Sales Volume: US$2.5 Million - US$5 Million
Registered Capital: US$101 Thousand - US$500 Thousand
Export Percentage: 71% - 80%
Factory Size: 1,000-3,000 square meters
QA/QC: In House
Number of R&D Staff: 5 - 10 People
Number of QC Staff: 5 - 10 People
  • Onsite operations checked and legal status confirmed
Tsingtao Toky Instruments Co., Ltd.

China Manufacturer with main products: Wood Moisture Meter, Textile Moisture Meter, Concrete Moisture Meter, Food Moisture Meter, Paper Moisture Meter, Grain Moisture Meter,...

Home  >Products Catalog > Moisture Meters > Multi-Parameter Water Quality Meter BT900

Multi-Parameter Water Quality Meter BT900

FOB Price: 1.00 - 100.00 USD/Piece
Payment Terms: T/T, Paypal, Western Union
In Stock
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Place of Origin: Shandong in China
Packaging Details: Parcel

Specifications

multi-parameter meter is capable of measuring up to 9

water quality parameters, including pH, ORP, Ion, Conductivity

TDS, Salinity, Resistivity, Dissolved Oxygen, etc.
 
General Features:

Automatic Temperature Compensation ensures high accuracy

    of measurements.

Calibration due reminder helps you to calibrate meter regularly.

Automatic endpoint function freezes stable measured values.

Help message as a operational guide to helps you understand

    how to use meter.

Setup menu lets user customize the calibration points, stability

    conditions, date and time to meet  measurement requirements.

Expanded memory stores and recalls up to 500 readings.

Built-in real-time clock stamps stored data to meets GLP.
USB communication interface.

 

pH Mode:

During the pH mode, Up to 5 points push-button calibration with auto-

    buffer recognition.

Selectable pH buffer standards and resolution (0.1, 0.01, 0.001pH).

Automatically calculates and  displays electrode slope  that helps you
    decide whether to replace pH electrode.
 
ORP Mode:

Single point  offset calibration allows user  adjusts displayed value to

    a known standard.
Absolute or Relative  mV measurements provides accurate readings.
 
Ion Mode:
Standard BNC connector can connects many Ion Selective Electrode.

2 to 5 points push-button calibration from low to high concentrations.

Selectable multiple concentration units, including ppm, mg/L, mol/L.

Direct readout ion concentration simplifies measurement process.

mV measurement allows user to check performance of ion electrode.

 
Conductivity Mode:

Up to 5-point push-button calibration allows user to uses customized

    calibration solutions.
Adjustable TDS factors, cell constants, temperature coefficients and
    normalization temperature (20°C or 25°C).
Selectable linear or pure water compensation modes.

In salinity measurement modes,  selectable practical salinity  (PSU) or

    seawater measurement standard (ppt).
 
       
 
Dissolved Oxygen Mode:

1 or 2 points auto-calibration (100% in saturated air or air-saturated

    water, 0% in zero oxygen solution).
Manual salinity and barometric pressure compensation.
Selectable readout in ppm, mg/L or % saturation.
 
 
  Specifications:      
     Model   Bante900      
   pH Range   -2.000~20.000pH    
   pH Accuracy   ±0.002pH    
   Resolution   0.001, 0.01, 0.1pH, Selectable
   Calibration Points   Up to 5 points
   Calibration Solutions   USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/ 12.75)
   Ion Concentration Range   0.001~19999ppm, mg/L, mol/L (Depending on measuring range of Ion Selective Electrode)
   Ion Concentration Accuracy   ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
   Calibration Points   2 to 5 points
   Calibration Solutions   0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm
   mV Range   -1999.9~1999.9mV
   mV Accuracy   ±0.2mV
   Resolution   0.1, 1mV, Selectable
   Conductivity Range   0~20mS/cm (Max.200mS/cm)
   Conductivity Accuracy   ±0.5% Full Scale
   Calibration Points   Up to 5 points
   Calibration Solutions   10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
   TDS Range   0~10ppt (Max. 20ppt, Depending on factor setting)
   TDS Accuracy   ±1% Full Scale
   TDS Factor   0.1~1.0 (Default 0.5)
   Salinity Range   0~10ppt (Max.80ppt)
   Salinity Accuracy   ±1% Full Scale
   Salinity Measurement Modes   Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
   Resistivity Range   0~100MΩ
   Resistivity Accuracy   ±1% Full Scale
   Resolution   0.001, 0.01, 0.1, 1, Automatic
   Temperature Coefficient   0.0~10.0% per °C
   Compensation Modes   Linear or Pure Water
   Cell Constant   K=0.1, 1, 10, Selectable
   Normalization Temperature   20°C or 25°C
   Dissolved Oxygen Range   0.00~20.00mg/L or ppm
   Resolution   0.01mg/L
   Dissolved Oxygen Accuracy   ±0.2mg/L
   % Saturation of Oxygen   0.0~200.0%
   Accuracy   ±2.0%
   Salinity Correction   0~50g/L
   Pressure Correction   60.0~112.5kPa, 450~850mmHg
   Temperature Range   0~105°C, 32~221°F
   Temperature Accuracy   ±0.5°C, ±0.9°F
   Temperature Calibration   Manual
   Temperature Compensation   0~100°C, 32~212°F, Automatic or Manual; DO Mode: 0~50°C, 32~122°F, Automatic
   Auto-Off   Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable)
   Hold Function   Manual or Automatic endpoint
   Stability Conditions   Low or High, Selectable
   Calibration due reminder   1 to 30 days or Off
   Reset Function   Yes
   Memory   500 data sets with Date/Time stamping
   Output   USB Communication Interface
   Connector   BNC and 6-pin connector
   LCD Display   Custom dual-display LCD (130×110mm)
   Power Requirements   DC5V, using AC adapters, 220VAC/50Hz
   Dimensions   210(L)×188(W)×60(H)mm
   Weight   1.2kg

 