Shenzhen Zoanco Electronics Co., Ltd.| Sourcing Services
Shenzhen Zoanco Electronics Co., Ltd.

China Manufacturer with main products: Flame Detector, Beam Detector, Heat Detector, Manual Call Point, Gas Alarm, Smoke Detector, Fire Alarm Control Panel, Bell

Home  >Products Catalog > 4 wire smoke detector > 4-Wire Ultraviolet Flame Detector UV Flame Alarm Sensor with Relay Output for Fire Alarm Protection

4-Wire Ultraviolet Flame Detector UV Flame Alarm Sensor with Relay Output for Fire Alarm Protection

Supply Ability: 10,000 Piece(s) per Month
Shipping: FOBshenzhen
Payment Terms: T/T, Western Union
  • ECVV Safebuy Services

    According to the requirements of buyers, ECVV.com will purchase the cost-effective Chinese products for you from the well-chosen suppliers database which was accumulated in the past 10 years.Learn More>>

  • Safebuy Service Guarantee

    Provide financial security for multinational purchaser; Determine delivery time and acceptance product according to the purchasing requirements; Arrange Chinese export declarations and international logistics; Provide unified delivery of products from different suppliers.

Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Place of Origin: Guangdong in China
Packaging Details: netural packing

Quick Details

  • Contact Load: Low Power
  • Protect Feature: Sealed
  • Size: Miniature
  • Theory: Voltage Relay
  • Brand Name: zoanco
  • Usage: Protective
  • Model Number: 6002
  • Operating Voltage Range: 12 to 28 VDC Volts
  • Standby Current: <10 mA @ 24 VDC
  • Alarm Current: <40 mA @ 24 VDC
  • Spectrum: 180~290nm
  • Detection Angle: 120 degree
  • Detection Sensitivity: Grade I, 25m@flame
  • Relay Contact Load: 1A@DC24V

Specifications

Skype firealarm87  /wechat 15220176087

GENERAL DESCRIPTION
the device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored.The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.

Specifications
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: 10 mA @ 24 VDC
Alarm Current 40 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20C to 55C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g
INSTALLATION
NOTE: All wiring must conform to applicable local
Codes, ordinances, and regulations.
Mounting Indoor Wall or Ceiling Products
1.Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output COM (ZONE+)
Terminal 2: Relay Output NO/NC (ZONE-)
Terminal 3: DC Power
Terminal 4: DC Power +
3. to attach product to mounting base.
4. Secure product by tightening the two mounting screws
in the front of the product housing.
5. the detector can be connected with Security alarm
Panel as Figure3. Relay output signal can be changed
from Normal Close (NC) to Normal Open (NO) by Jump
JP1 on the PCB board.
6. the detector can be connected with conventional alarm
Panel as Figure 4. One 4.7K ohm resistor should be
Connected as End of Line (EOL) resistor at the last
Detector.
7. after the installation, power on the detector, use lighter
or candle to test the detector within 3 meters.
4wire Ultraviolet Flame Detector UV flame alarm sensor with Relay Output for fire alarm protection


uv flame detector from this supplier

Acrel 300286. SZ Residual Current Relay Protection Relay ASJ20-LD1A Operation with Circuit Breaker    
FOB Price: 112.00-130.00 USD/Acre
Min Order: 1 Acre
PID Digital Temperature Controller REX-C100(M) 0 to 400 Celsius K Type Relay Output    
FOB Price: 4.86 USD/pieces
Min Order: 103 pieces
H3CR-A8 Time Relay 1.2S-300H 8-Pin Knob Control Delay Timer Relay 100-240V AC 100-125V DC    
FOB Price: 12.73 USD/pieces
Min Order: 40 pieces
Universal 0-10 Seconds Knob Control Timer Relay AH3-3 Delay ON Time Relay with Base AC 110V 5A Socket Rotary Knob Hot Sale    
FOB Price: 11.96 USD/pieces
Min Order: 42 pieces
220V 5A on off Twin Timer Relay Knob Control Time Relay Switch 6S-60M ATDV-NC    
FOB Price: 14.47 USD/pieces
Min Order: 35 pieces

More products from other suppliers

Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.

Learn More>> Start Safebuy Order

Communicate with Supplier

Ms. Jenny Ning
Join Facebook Group