Quick Details
- Brand Name: Grandtop
Specifications
Application
The equipment can check whether it reaches thermal equilibrium and the disconnector is in operation or not.
Standard
IEC61643.1-2005, GB18802.1-2011
Advantages and Features
(1) The voltage and current value and real-time curve are displayed automatically on the computer interface.
(2) Automatic product test
(3) High accuracy
(4) K-series electrical coupling measures the temperature precisely
(5) High voltage protection: red and green lights indicating the status, scramming button, the door interlock.
(6) Plexiglass covering and safety interlock on the test area
(7) Over current protection on the main loop
(8) The casting of control cabinet is grounding and test circuit always grounds at one end.
Technical Specification
? Power input: AC220V/3kVA,single phase 50Hz
? Output voltage: Max. DC1500V
? Output current: Min. DC <2mA, max. DC 2A
? Voltage waveform: DC voltage ripple coefficient ≤5%
? Current adjustable range: 1mA-2A which is divided into 4 degrees are separately for testing the following data: 0-10mA, 10mA-100mA, 100mA-1A, 1A-10A. The output current control accuracy is in the range of ±10%
? HV safety security: It's equipped with red and green indicate lights, emergency stop and EUT door interlock
? The test area was designed with organic glass hood and safety interlock