Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Jiangsu in China |
Quick Details
- Brand Name: kccv
Specifications
Definition
JK-GPB serise pressure transmitter imported organic silicon diffusion, ceramic pressure sensor as the sensing element, adopts a special integrated module, fine temperature drift, zero, nonlinear compensation, to achieve accurate measurement and on the changes of the medium level, gas, steam pressure to send.Implementation of industrial and mining enterprises, scientific research institutes such as the ideal monitoring departments in various places pressure vacuum.
Product characteristic
Service: liquid, gas and steam
JK-GPB serise pressure transmitter main technical parameter
| 0.1%F.S,0.25%F.S,0.5%F.S | |
measuring range | -95KPa~60MPa | |
measuring medium | liquid,gass,steam | |
Storage temperature | -40°C~125°C | |
using temperature | 10°C~80°C | -40°C~80°C |
temperature effect | <0.02%/°C | <0.015%/°C |
antiseptics | SUS316L | ceramics teflon |
load resistance | ≤750Ω | |
overload capacity | range1~2times | |
humidity | ≤95%RH | |
export | two-wire system4~20mA DC(LED scene shows three-wire system) | |
weight | about 1Kg |
1. Measuring range : 0~0.06 kPa to 0~40Mpa
2. Output signal : 4~20mA DC (four-wire 220V AC power supply, 0~10mA DC output for special)
3. Power supply : 12~45V DC, generally 24V DC
4. Features of loading: relation equation of loading impedance RL and power voltage
Vs: RL <= 50(Vs-12)
5. Indicator : pointer-type linearity indication 0~100% scale mark or LCD indicator, LED indicator.
6. Explosion proof : a. explosion isolation d II BT4
b. intrinsically safe ia II CT6
7. Positive and negative shifts : after positive and negative shifts of zero absolute values of upper-and-lower-limit values of span and measuring range not exceed 100% of upper limit of measuring range.( smart type : turn down ratio 20:1, 40:1, 100:1)
Maximum positive shift is 500% of minimum adjusting span; maximum negative shift is 600% of minimum adjusting span.
8. Temperature range: amplifier operation temperature range: -29 ~ +93C
(LT type: -25 ~ +70C); measuring component of fill silicone oil: -40 ~ +104C
flange type transmitter fill hi-temperature silicone oil: -20 ~ +315C normal silicone oil: -40 ~ +149C
9. Static pressure : 4, 10, 25, 32Mpa
Humidity : relative humidity 0~100%
10. Volume absorption : < 0.16cm3
11. Damping (phase step response) : For silicone oil, generally between 0.2s and1.67s, continuous and adjustable