Wuhan Precision Measuring Equipment Manufacturing Co., Ltd.
China Manufacturer with main products: Standard Voltage/Current Transformer, AC Test System, DC Resistance Tester, Partial Discharge Test System, Impulse Voltage Test System, Multi... |
PMDXC Electric Harmonic Measuring tester,Alarming and Analyzing Instruments
FOB Price: | 1,999.00 - 2,700.00 USD/Set |
---|---|
Supply Ability: | 20,000 Set/Sets per Month |
Shipping: | two work days delivery time, from Shanghai & Shenzhen port, etc |
Payment Terms: | T/T, Western Union |
Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Hubei in China |
Packaging Details: | IPPC International standard wooden boxes packing |
Quick Details
- Three-phase voltage & current: Measuring times of harmonics: 5-51
Specifications
PMDXB Alarming and Analyzing Instruments,
PMDXC Electric Harmonic Measuring tester,
It meets whole requirements of GB/T1459~93 test virtual value, and positive ,reverse and zero sequence component of current and voltage
Measuring area: content of voltage harmonic, distortion factor of phase-angle and current voltage
Virtual value of current harmonics, distortion factor of phase-angle and total voltage harmonics
Range of measuring harmonics: fundamental wave -51times harmonics
Way of input signals: voltage, current & phase
Print: printed three-phase waveforms, statistic of the testing results, automatic printed three-phase results.
The key technical indexes:
1.Way and range of input signal
A.Three-phase voltage and three-phase current
B. voltage test range: 10-240V(or 20-400V)
C. current test range: 0.05-6A (or0.1-12A)
D. tracking range of fundamental harmonics frequency
2. Input impendence: voltage side≥200kΩ, current side≤20mΩ
3. Measuring accuracy: measuring error of fundamental: ≤0.5%
4. Measuring times of harmonics: 5-51
5. Statistical times: 5~96 times are choiceable
6. Timing space of orientation in time: 0~999 minutes are choiceable
7. setting range of continuous limited number: 0~999
8. time of equipments' power supply source: 220V±15%; 50Hz±5%; THDu±≤8.0%; 20VA
More products from other suppliers
Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.
Learn More>> Start Safebuy Order