Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Shandong in China |
Packaging Details: | wooden case with inner plastic bag |
Quick Details
- Rated Current: 108A
- Rated Voltage: 400V, 220V, 440V
- Rated Power: 75KVA/60KW
- Frequency: 50/60HZ
- Speed: 1500/1800RPM
- Output Type: AC Three Phase
- Model Number: SP60GF-Z
- Brand Name: SUPERMALY
Specifications
1. Main technical specification of Biogas generator 60kw
Model of generating sets |
SP60GF-Z |
Model of engine |
SPC6114ZLDZ |
Rated power |
60KW |
Standby power |
66KW |
Rated speed r/min. |
1800 |
Rated frequency Hz |
60 |
Rated power factor |
0.8 |
Gas consumption |
0.46Nm3/kw.h |
Supply method |
3 phases 4 lines |
Excitation method |
brushless |
Starting method |
24V DC starter 24V |
Cooling method |
Water tank and fan |
Speed modulate method |
Electronic control |
Net weight kg (open type) |
2200 |
Overall dimension L×W×H(mm) (open type) |
2500*1050*1700 |
Main technical data of engine
Model of engine |
SPC6114ZLDZ |
Engine brand Rated power/speed |
Cummins 70KW/1800rpm |
Specific oil consumption |
≤1.6g/KW.h |
Oil capacity |
20L |
Number and layout of cylinders |
6cylinder, inline |
Type |
Four stroke, water cooled, turbocharged and intercooling, spark plug ignition |
Bore |
114mm |
Stroke |
135mm |
Direction of rotation (facing to end) |
Counter-Clockwise |
Lubricating method |
Pressure and splash lubrication |
Function :
1. Adopt Genset controller with LCD display, taking microprocessor as the core.
2. Adopt ATS( automatic transfer switch) to achieve the automatic transfer from the generated electricity to grid electricity
3. The monitor and display on the voltage, current, frequency, active power, apparent power, power factor of the generated electricity /grid electricity
4. The monitor and display on the genset's water temperature, oil pressure, rotational speed, battery voltage, running hours, accumulative total power and number of starts
5. Protection alarm and fault automatic storage on high water temperature, low oil pressure, double speeding, over current, over voltage, over frequency and phase failure etc.
Optional devices :
CHP device, Soundproof cabinet, automatic grid parallel connection device, emergency cooling system etc