Home  >Products Catalog > hotel card lock > Orbita ESS-30 RFID Hotel Power Switch,Hotel Energy Saving Switch ,Energy Saving Power Switch

Orbita ESS-30 RFID Hotel Power Switch,Hotel Energy Saving Switch ,Energy Saving Power Switch SafeBuy Supplier Member

FOB Price: 3.00 - 12.00 USD/Piece
Supply Ability: 100,000 Piece/Pieces per Week
Shipping: 7days after payment
Payment Terms: L/C, T/T, Western Union, Paypal
In Stock
Export Markets: North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Place of Origin: Guangdong in China
Packaging Details: 1pc/polybag; 100 pcs/ carton; 15 kgs/ carton; carton size: :47cm X 24cm X 38CM Seaworthy pac

Quick Details

  • Mechanical Life: 10years
  • Max. Voltage: 240V
  • Max. Current: 120A
  • Size: 86*86MM
  • Model Number: ESS-30
  • Brand Name: ORBITA
  • Material: Plastic
  • Logo: Available
  • Color: white,black ,ice cream ect
  • Type: RF,Mifare,General
  • Feature: use for hotel room energy saving
  • mounted box: we have
  • OEM/ODM: Yes
  • Certificate: CE
  • Output: 3 phase output
  • Warranty: 3years

Specifications

Orbita ESS-30 RFID hotel power switch, hotel energy saving switch , energy saving power switch


1. Basic Parameter

Insert card switch Size: 86mm*86mm

Controlling box size: L210mm*W110mm*H50mm

Input/ Output Voltage: AC 100V-150V/ AC180V-240V


For Mifare card type: ESS-40

For Temic RF card type: ESS-30

For IC card type: ESS-10

For Magnetic card type: ESS-11

For general use: ESS-00



Energy saving switch function:


  • Both a power switch and energy saver which is used to save electricity for rooms for inns, hotels or any school dormitory or house .. Etc Guests or persons insert the smart cards into the socket to gain the power for the rooms or take out the cards from the socket to cut off the power for a room.
  • Saving cost of manegement for hotels, office and appartment, etc, and the same time, reduce consumption of electric resource to protect surrouding environment.


Energy saving switch is used for following 6 types:


  • ordinary energy saving switch( Can accept any card to gain the power. )
  • IC chip card energy saving switch( Only accept IC chip outside card to gain the power. )
  • 125KHZ card (Such as Temic or EM card) energy saving switch( Only accept 125KHZ card to gain the power. )
  • 125KHZ card (Temic card) energy saving switch( only accept programed Temic cards with room number to gain the power)
  • 13.56MHZ card (such as MF 1K card) energy saving switch( Only accept 13.56MHZ card to gain the power. )
  • 13.56MHZ card ( MF 1K card) energysavingswitch( only accept programed MF 1K cards with room number to gain the power)


Outstanding Feature:


Orbita supply energy saving switches which can be operated by insertion of a hotel room door key card or a special key fob or tag. These energy saving switches reduce energy costs and produce a speedy return on investment. Our switches work with the major hotel access control equipment produced by manufacturers such as Vingcard, Onity, Kaba, Cisa etc.


Hotel card key switch turns electrical circuits on or off when a key card is inserted or removed from its slot. Energy-efficient hotel card key switch, helping the hospitality industry reduce energy consumption in empty hotel rooms.


This assures that when guests are not in their room, energy will not be wasted on lights or appliances left on. When a guest enters a room, guests key card is inserted into a docking station. After the key card is inserted, infrared signal is obstructed or RF contactor/non-contactor is activated subsequently "energizes" the hotel guest room. When the key card is removed from its dock, the controlled circuits will have power for another 15 seconds to allow safe exit from the room before power is turned off. To restore power to the rooms controlled circuits; reinsert the hotel key card into the card key switch.


By reducing the amount of energy exhausted on lighting, heating and cooling unoccupied rooms, with hotel card key switch, hotel owners can reduce energy consumption up to 30 percent. When factoring lower power bills, the hotel can recoup initial installation costs in less than 4 years. Architects and contractors can now modernize a hotel without running wires to the controls. No special wiring or networking expertise is required.


In a word, with Hotel Card key switch, facilities managers in the hospitality industry can easily comply with current energy save without compromising guest comfort and satisfaction

Other products from this supplier

Lock (E1180 )    
FOB Price: 68.00-80.00 USD/Piece
Min Order: 1 Piece
E1010S    
E1340    

Can't find a suitable Supplier or product? Entrust ECVV to purchase the well-chosen Chinese products with high cost performance.

Learn More>> Start Safebuy Order

Communicate with Supplier

Ms. Ellen Feng
Join ECVV community
Join Facebook Group