Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Guangdong in China |
Packaging Details: | SUPER-HEAT PACKING, 13cm*27cm*29cm, MTR BOX |
Quick Details
- Usage: Universal Testing Machine
- Power: Electronic
- Model Number: GDS-5B
- Brand Name: Wisdom Source
- accuracy: better than 0.2ppm
Specifications
1. Overview
The new GDS-5B quartz watch tester is
suitable for precisely testing all kinds of clock circuits with crystal
oscillator working at 32.768KHz and 1Hz, for example: quartz clocks, electronic watt-hour meter, motherboard, temperature
controller, timer, electronic weigher and electronic cash register with timer function.
Its appearance is depicted as Figure.1.

Figure.1 GDS-5B quartz watch tester
GDS-5B quartz watch tester especially suits the fast testing of finished products or semi-finished products. GDS-5B's RS232 interface can be used to connect GDS-5B and computer in order to gather testing results. Additionally, our GDS-B quartz watch tester has a tinny probe with it, which can suits the testing of bigger circuit boards.
GDS-5B has five stalls:
: part per million, accurate to 0.1ppm
u s/d: seconds/day, accurate to 0.01 seconds
u s/m: seconds/month, accurate to 0.1 seconds
u s/y: seconds/year
u F:32.768KHz frequency deviation
Compared with the same type of products from other companies, our GDS-5B has the following advantages:
u with a more sensitive sensor in it to receive weak signal;
u taking non-contact method;
u thinner shell making it more easy to use and more suitable for the pipeline;
u with advanced CPU and TCXO(Temperature Compensated Crystal Oscillator);
u with a 16-level signal strength indicator;
u with the function of alarming, and the user can set alarming range;
u easy setting procedure;
u accuracy is better than 0.2ppm;
u extra: RS232 to connect GDS-5B to a computer
2. Featuresu measuring objects: quartz clock, electric meter and clock circuit board
u voltage:85V-135V 170-250V AC 50Hz-60Hz
u testing frequency: 32.768KHz 1Hz
u measurement period :1s, 2s, 5s, 10s, 20s, 32s, 60s
u reference frequency:16.384MHZ TCXO
u testing accuracy: better than 0.2ppm
u range: ppm: part per million; s/d: seconds/day; s/m: seconds/month; s/y: seconds/year; F:32.768KHz frequency deviation
u signal strength indicator:16 level indicator
u alarming setting range:±200ppm
u volume: 13cm*27cm*29cm
u display mode: four-digit LCD display
u extra: RS232 to connect GDS-5B to a computer