Sicon 3 Phase LCD Uninterrupted Power Supply UPS 50-800kva Modular UPS
Supply Ability: | 500 Set(s) per Month |
---|---|
Shipping: | Tianjin port, 28 delivery days |
Payment Terms: | T/T |
-
ECVV Safebuy Services
According to the requirements of buyers, ECVV.com will purchase the cost-effective Chinese products for you from the well-chosen suppliers database which was accumulated in the past 10 years.Learn More>>
-
Safebuy Service Guarantee
Provide financial security for multinational purchaser; Determine delivery time and acceptance product according to the purchasing requirements; Arrange Chinese export declarations and international logistics; Provide unified delivery of products from different suppliers.
Export Markets: | Eastern Europe, Southeast Asia, Mid East, Eastern Asia, Western Europe |
---|---|
Place of Origin: | Hebei in China |
Packaging Details: | wooden case |
Quick Details
- Application: Security / Monitoring / Alarm
- Type: On-line
- Protection: Overvoltage
- Phase: Three Phase
- Brand Name: Sicon
- Output Voltage: 384V
- System capacity: 10-800KVA
- Power module capacity: 10/25/50KVA
Specifications
Basic Information
Truly Modular UPS
Full UPS functioned UPS Module
Choice of UPS Module (10kVA, 25kVA, 50kVA) result in Rational Redundancy
Modular, hot-swappable, field-replaceable STS, Monitor, UPS module
Scalable from 10kVA to 800kVA. Parallel-capable up to 3200kVA.
Overview
CMS UPS units are non-isolated, industrial level, green UPS, adopting advanced modular power protection concept. CMS Modular architecture can scale power as demand grows or as higher levels of availability are required. CMS UPS is industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments.
Feature
Rational redundant structure
UPS module: 10 kVA, 25 kVA, 50 kVA; System: 50kVA, 100 kVA, 150kVA, 250 kVA, 350 kVA, 500 kVA, 800 kVA.
Great performance index: overall efficiency 95%(AC-AC), inverter efficiency 98%(DC-AC), THDI 3%, and input PF 0.99
N+X module-level redundancy UPS System
Multi-level decentralized control technology and Master-slave synchronization in sequency control which result in eliminate system failure bottleneck
Each module automatically even shares the input and output current, all UPS modules share batteries
Battery Management Function:
Battery discharge management, auto-transfer between floating and even charging, temperature compensation
Space-saving high density design, Rack-based for agility and aesthetics
Monitor Function
C/S-Oriented Architecture SICON Software which is available to monitor multiple UPS up to 600 sets; B/S-Oriented Architecture which is available to check via IE
Standard configuration
Manual maintenance bypass, SPD(Class C), RS232, RS485/RS422 Communication ports, Remote monitor software, day contacts
Optional configuration
EPO, Input/output Transformer, Battery Bank, IPDS(Intelligent Power Distribution System)
System model |
CMS-50/10 |
CMS-100/10 |
CMS-150/25 |
CMS-250/25 |
CMS-350/50 |
CMS-500/50 |
CMS-800/50 | |
Maximum power |
50 kVA |
100kVA |
150 kVA |
250 kVA |
350 kVA |
500kVA |
800KVA | |
Power module model |
10 kVA |
25KVA |
50KVA | |||||
Mains Input |
Input mode |
3-phase +N +E, 1-phase +N +E | ||||||
Input voltage |
380V/220V20%, 400V/230V20%, 415V/240V20% | |||||||
Input frequency |
50Hz10%, 60Hz10% | |||||||
Power woke-in (Sec.) |
60sec | |||||||
THDI (%) |
<3% | |||||||
Input PF |
0.99 | |||||||
Bypass Input |
Input voltage |
380V/220V20%, 400V/230V20%, 415V/240V20% | ||||||
Input frequency |
50 Hz, 60 Hz | |||||||
Range of Frequency Synchro |
50 Hz4%, 60 Hz4% | |||||||
DC Input |
Rated Input voltage |
384VDC | ||||||
Input voltage tolerance |
345V~440V DC | |||||||
Battery charging |
Charging current limited |
yes | ||||||
Charging ability |
10 hours (2 hours back up) | |||||||
Stability of charging voltage |
1% | |||||||
AC output |
UPS power factor |
0.9 | ||||||
Output voltage |
380V/220V AC, 400V/230V AC, 415V/240V AC | |||||||
Output frequency |
4%;0.2% (battery supply) | |||||||
Output voltage stability |
1% | |||||||
Output voltage recovering time |
<20ms(load 0~100% change) | |||||||
Overload ability |
Operate 10mins with 125% load | |||||||
Transfer from mains to battery supply |
0ms | |||||||
Transfer from bypass to inverter supply |
<1ms | |||||||
Peak factor |
'3:1 | |||||||
Waveform distortion |
1% ( linear load ), 3%( non-linear load ) | |||||||
Overall efficiency |
95% (AC~AC), 98% (DC~AC) | |||||||
Load share precision |
5% | |||||||
Operation environment |
Ambient temperature |
-25~60 | ||||||
Operating temperature |
-5~40 | |||||||
Maximum operation altitude |
1500m | |||||||
Relative humidity |
95% non-cadency | |||||||
Protection degree |
IP30 | |||||||
Cooling |
Air cooling | |||||||
Applicable safety standards |
EN62040-1-1:2003 IEC60950-1:2001 | |||||||
Electromagnetic compatibility |
EN62040-2:2006 | |||||||
Acoustic noise |
55DB | |||||||
Others |
Cabinet |
Standard 19 inch cabinet | ||||||
Monitor management system |
UPSupervisor | |||||||
Interface |
RS232, RS485 and 8 try contact, TCP/IP adapter, SNMP(optional) | |||||||
Display |
Touch LCD/LED Screen | |||||||
Weight(kg) |
150 |
200 |
200 |
260 |
400 |
500 |
700 |